6T Boiler Oil Fired Steam Boiler

6T Boiler Oil Fired Steam Boiler

Multiple protection devices take you through the oil 6t boiler fired steam boiler oil steam boiler water level protection, boiler water level gauge plate supporting one to two, should always be compared with each other, findings indicate inconsistency shall be corrected immediately. Class water level should be flushed, to determine their true level. While the water level comes electrode rod can accurately capture level signal to an alarm or a pump control. Steam pressure protection, the pressure controller: selection of high sensitivity of the pressure controller, the pressure is high, or low levels of signal to the electrical switches, automatic control chain protection or other control lines. Using pressure controllers and electrical contacts, the vapor pressure can overpressure alarm; single adjustable pressure controller or dual fire burning fire the actual operating pressure. Safety valve: safety valve is the last line of defense to protect the boiler, the boiler pressure exceeds the limit, according to the set pressure relief valve design with the school, the exhaust steam pressure relief, to ensure the normal operation of the boiler. Flame protection, having imported burner flame protection means, combustion function is to detect, when the ignition failure or extinguish combustion middle, immediately off the burner into the oil (gas) solenoid valve, the blower continues to operate at this time, the furnace was purged of residual internal combustible gas, after 20 to 30 seconds purge, and various auxiliary blowers automatically cut off power, the boiler operation stops. Self-locking power protection case, the boiler shutdown immediately burst self-locking power interruption, if the current power is restored, the boiler will not start at any time, you must reset release self-locking, to re-start the ignition.

At the end of 2017, China Guodian is located in Jiangxi Province Wanan Hydropower Plant After evaluating the situation, some of the 6t boiler fired steam boiler used to purchase much-needed daily work. Sales Manager fast boiler combined with the actual situation of the power plant for its recommendation 2 0.5 tons of electrically heated steam boilers.

What impact have fuel moisture 6t boiler fired steam boiler? Most of the aqueous fuel when coal or heavy oil with steam atomization of entrained moisture in an amount not more than 5%, no effect on the coil and the inner shell boiler, the boiler because their materials are steel, steel are mainly: 20g, 16Mng, 15CrMoVg, 19Mng, 22Mng, with a strong antioxidant, water resistance. With more moisture, combustion performance worse, if the moisture up to 40% burn will be extinguished.

Check the work before the start fuel gas-fired boiler in order to protect the safe operation of the gas boiler, improve operational efficiency boiler, make sure to check the work before the boiler starts, every detail can not be ignored. 1, check the safety accessories, thermal instrumentation, electrical instrument should be intact; 2, check the connections, whether the water leakage and the furnace body line; 3, check the waste line, the water line, return line should be smooth; 4 , should check the line voltage is 380V, the fluctuation should be within ± 5%; 5, oil-fired boiler and a filter pump check whether normal oil, gas boiler check the gas pressure is normal, not too high or too low, the oil supply opening valves; 6, check whether the pump Sheung Shui, or opening the purge valve, until the Sheung Shui so far. Water Supply System opens each valve (including the water pump and water valve before and after the boiler); 7, check level gauge, the water level should be in the normal position, to prevent false water level, if the water can be manually Sheung; 8, check the pressure conduit the valve must be opened, the wind deflector must all flue opening; 9, each knob inspection control cabinet are in their normal position; 10, a check valve should be 6t boiler fired steam boiler in a closed state, the hot water boiler circulating pump valves should be closed state; 11, check water softening equipment is operating correctly, create a variety of indicators of soft water meets national standards. Carefully do the above inspection, the basic conditions for the fuel gas boiler safe and economic operation.

Free Chat

About Us

Contact Us