Run and long-run process of the initial operation of the gas steam 15 ton diesel fired boiler malaysia water level control gas steam boiler, steam drum water level will not change because of different working conditions, should be timely adjusted. Steam boiler is an energy conversion device, the energy input to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output having a certain outside thermal energy, high-temperature hot water or an organic carrier. 1. When the boiler operation begins, the water vapor expansion in the furnace after heating, resulting in gradual increase in the water level, to be noted that at this time, the door can not be reduced by the sewage water level in the accident, the water can be discharged from the discharge gate, so as to ensure the normal circulation in the furnace . 2. When checking security door, due to the increased steam flow and reduce the vapor pressure, the water level will be false. Thus, prior to preparing the above-described operation, it is necessary to maintain the water level in the furnace at a low state, then the amount of water used according to the water level change. 3. Since the steam temperature and steam pressure changes, as well as the increased displacement, the operator needs to periodically check the water level changes, the amount of water added. Function gas boiler the ignition system that ignites the mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas boiler manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. The load condition of the gas steam boiler, automatic water supply means can be added, and the timely replacement of running water during operation. Function gas boiler the ignition system that ignites the mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas boiler manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. These are gas steam boiler water level control in operation, gas steam boiler is to introduce. I hope this has helped everyone.

It is necessary to periodically check the parts to ensure flexibility electric 15 ton diesel fired boiler malaysia electric boilers, also known as electric heating boilers and electric boiler. As the name implies, it is a boiler plant, which uses electricity as energy and convert it into thermal energy, so that by converting boiler steam, hot water or organic heat is converted into heat. Electric boiler by a boiler main body electrical steel housing, computer control systems, low-voltage electrical systems, heating pipes, water pipes and out of the detection-instrument. Under normal circumstances, before you install electric boilers do not rush to power. First, you must cycle test. Sometimes, when you test it, you will find an electric boiler drainage. Here we will break down the cause. This phenomenon is mainly due to the incorrect installation of electric boilers, circulating pump installed in the inlet electric boiler. Greater than the amount of water back into the water electric boilers. When the return is greater than the amount of water into the water, will form a counter-current, natural vent will form a bubble, this is what we usually refer to ventilate the water. The solution to this problem is to install the correct position of the circulation pump. Typically, small electric power to drive the boiler heating and hot water supply. It is much safer than gas-fired boiler. No danger. Before operating the electric boiler, be sure to read the product manual carefully and follow the instructions. Before starting small electric boiler, double-check the water, power and voltage, to ensure that no exception. Drain valve opens the water supply valve, the pump checks whether the jam. When the electric boiler in need of repair, to turn off the power; kept clean and dry small electric boiler. It is necessary to periodically check electrical safety components of the boiler, check to ensure flexibility. Each year, the local quality and technical supervision departments should carry out a large number of checks. The method comprises electric heating boiler electromagnetic induction heating method and resistance (electric heating) heating method. A resistance heating method is divided into stainless steel heating tubes and a ceramic heating tube electric boiler electric boiler, resistance heating by a resistance heating electric tubular element. heating. Electric boiler simple structure, compact, flexible control, easy maintenance and replacement.

What is that 15 ton diesel fired boiler malaysia soot blowers? What impact on the operation of the boiler there? Soot Blower concept: long-term operation of boiler, heating surface fouling and coking occur, so that the deterioration of the heat transfer for the back pass, because the long-term accumulation of fuel, and then burning accident will occur which results in the boiler section after the time needed to work soot blowing heating surface, to clean the heating surface.

Recently, the Tianjin Municipal Government issued the latest "2018 ~ 2019 autumn and winter tackling air pollution comprehensive management action plan" (the "Program"), "plan" put forward specific remediation requirements: the city's 65 steam tons / hour and above the basic realization of coal-fired 15 ton diesel fired boiler malaysias coal-fired power plant ultra-low emission standards, the development of energy-saving and ultra-low emissions rehabilitation programs for 65 steam tons / hour or more coal-fired boilers, the implementation started after the end of the heating season. Before the end of this year, within the city basically eliminated 35 tons of steam / h and coal-fired boilers of 25 iron and steel industrial enterprises discharge waste depths of governance, the basic completion of the iron and steel, building materials, thermal power, coking, casting and other key industries and coal-fired boiler fugitive emissions control.

"Plan" the implementation process to uphold the objectives warm winter and clean heating double standards, combined with the actual development of coal-fired boiler rehabilitation programs, to ensure completion before the end of the year 206,100 rural residents to use clean energy alternative to coal for combustion. Guidelines established after the first break, for the substitution of gas for coal to electricity instead of coal and other alternatives, in the case of gas supply, power supply is not implemented, the existing heating facilities will not be dismantled until the gas supply, power supply after the successful implementation be removed. And to develop high-pollution fuel combustion zone ban zoning adjustment programs, complete with electricity instead of coal, substitution of gas for coal in the region included the range of high-pollution fuel combustion zone ban. For failure to implement the heating area clean, good smokeless coal tender, production, supply, to ensure smokeless coal substitute the existing polluting large coal-fired boilers. Among them, before the heating period to complete large-scale centralized distribution, heating Doing the fragmented coal blending, before the end of December 2018, the actual realization of bulk coal dealers cleared.