High Quality Oil Fired Steam Boiler

High Quality Oil Fired Steam Boiler

Function of different types of gas boiler is not the same for each fuel boilers are not the same, with some coal to burn, some with gas or fuel oil to burn, but also some combustion power, as well as the use of coal-water as a raw material slurry of combustion. Some gas boiler is also been called a gas furnace. This is generally used for boiler fuel, but fuel is also classified, some heavy, some light oil. If the raw materials are burning gas, then this can also be classified, some inside the city gas use, there is natural gas. Burning hot water boiler to heat water to a boil, whether kerosene or gas as raw material are possible. The use of gas to boil water in the boiler, use gas to heat water in the boiler, use gas to generate high quality fired steam boiler works, etc. belong to this series of boiler gas boiler. Use hot water boilers to burn gas, it has a name, that is the use of gas to provide heating boiler, there is the use of the gas boiler can boil water and take a bath. This boiler can be inferred from the name on it out of the raw materials used are burning gas. In use among gas boiler and boiler fuel use and the use of electric power boiler combustion, they are more affordable economy. But the most inexpensive gas boiler or the use, of course, this is the choice of many people. Gas-fired boiler is very common in daily life, a lot of heating, bath facilities are of this boiler. The benefits of using gas to boil water can be more, not only a short time to boil water, and gas usage is not too much, so that more of the cost.

Gas boiler market prospects of geometry: divided by fuel coal, fuel (gas), electric steam furnace. Fuel oil (heavy oil and light oil is divided) gas (divided city gas and natural gas) hot water boilers that burn oil or gas fired boilers can heat the water. Development of sub-pot boiler and furnace two aspects.

Gas boiler Burner Failures and gas boiler burners Failures and - best  a gas boiler, gas boiler burner ignition misfire rod reasons: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs. Measures following five: Clear, renewal, adjust the distance, change and switching transformer. Second, gas boiler, but spark ignition rods misfire reasons: 1, the cyclone disc space ventilation is blocked carbon, poor ventilation. 2, dirty oil nozzle clogging or wear. 3, the throttle angle is set too small. 4, the firing bar from the leading edge from the oil nozzle tip inappropriate (too protruding or retracted) 5, the first solenoid valve is an oil debris blocking gun (gun small kerosene). 6, oily or too viscous to flow easily clogged or the oil filtration system the valve is not opened, so that insufficient suction pump, oil pressure. 7, the filter pump itself blocked. 8, the oil more water (boiling abnormal noise within the heater). Measures are: Clear; first wash, such as not renewed; turndown test; adjusting the distance (in 3 ~ 4mm as well); Remove cleaning (cleaning the parts diesel); Check tubing and oil filters, insulation equipment ; remove peripheral screw pump, carefully remove the cover inside out oil network, with immersion oil; renewal of the test oil. Third, when the gas boiler and turn the fire a small fire normal, off, or flashing instability reasons: 1, the air volume damper setting fire too. 2, oil fires micro switch valve (damper outermost that group) inappropriate setting (set throttle air flow rate is greater than the fire). 3, oleaginous easy to spray viscosity is too high (heavy). 4, and the nozzle plate spacing cyclone inappropriate. 5, fire nozzle worn or dirty. 6, the preliminary fuel tank temperature is too high, so that the steam not smooth oil pump oil feed. 7, fuel oil boiler water. Action: Test gradually reduced; heating temperature; adjusting the distance (between 0 ~ 10mm); clean or replace; approximately set to about 50 deg.] C; or drain oil change. Fourth, the noise increases gas boiler burner reasons: 1, cut-off valve is closed or the passage into the fuel shortage, an oil filter blockage. 2, the oil inlet temperature is low, the oil viscosity is too high or the temperature is too high the pump inlet. 3, oil pump failure. 4, fan motor bearing damage. 5, dirty fan impeller. Processing methods: ① the oil line check valve is open, if the oil filter is working properly, the filter cleaning pump itself. ② heating oil or reduce the oil temperature. ③ Replace the oil pump. ④ replace motor or bearings. ⑤ cleaning fan wheel.

Luzhou, Sichuan issued a notice to win the Battle of Blue Sky embodiment. Program requirements, to promote ultra-low emissions to upgrade the steel and cement industries, and increase efforts to eliminate small coal-fired boilers, phasing out the whole 10 tons / hour and below the coal-fired boilers. Details are as follows.

1, to accelerate the development of clean energy. Scientific and orderly promote clean energy development and utilization of hydropower, natural gas (shale gas), wind power, solar, biomass and so on. By 2020, the city's total primary energy consumption of 12.48 million tons of standard coal, total coal consumption control in less than 6.5 million tons, accounting for the proportion of total energy consumption control in less than 42%, the newly constructed and put into operation a large municipal solid waste incineration power plants, garbage power generation capacity of 12MW, a new wind farm installed capacity of 48MW, the development of distributed PV installed capacity of 5MW, the new large biogas 5. Improve the construction of reservoirs for natural gas production and marketing system.

2, to promote the use of clean coal. Efforts to increase coal washing, coal simultaneous construction of new coal washing facilities, supporting the completion of existing coal mines coal washing facilities in accordance with points Area. Improve coal quality and use of standard industrial, commercial coal do not comply with environmental standards required by regulations of coal quality merchandise. Prohibit the circulation and use of low-grade bulk coal, bulk coal investigated and dealt with according to the law without a license behavior. Increase the civil bulk coal clean governance efforts to promote electricity instead of coal, substitution of gas for coal, to promote the use of clean coal, advanced civilian stoves, strengthen civil bulk coal management. Strengthen regulation and control coal use in autumn and winter.

3, to carry out comprehensive improvement of coal-fired boilers. Increase efforts to eliminate small coal-fired boilers. By 2020, the county level and above cities phasing out the built-up area per hour and 10 tons of steam coal-fired boilers, in principle, to a new 35 tons of steam per hour of coal-fired boilers, in principle, to other parts of the new 10 per hour tons of steam coal-fired boilers. Ambient air quality standards are not areas should further increase efforts to eliminate.

4, increase Condensing units and cogeneration units technological transformation efforts, speed up the heating pipe network construction, fully release and improve the heating capacity, eliminate network and bulk coal fired boilers within the coverage area. In areas not have cogeneration district heating conditions, a plurality of existing coal-fired boilers of small, actively promote the implementation alternative energy.