5 Mw Gas Fired Industrial Boiler

5 Mw Gas Fired Industrial Boiler

Gas-fired steam 5 mw fired industrial boiler abnormal situation, how should we deal with it? When we use gas steam boiler, failure or abnormal phenomena it is inevitable, but in order not to affect the normal use, in the event of a problem gas steam boiler to be timely processing solutions, then the face of all kinds of circumstances, we should how to handle it? Share some of the ways we deal with unusual circumstances. If only gas steam boiler circulating pump abnormalities, such as its current decreases, the pump outlet pressure back to zero, which indicates no oil pump is idle, it may be caused by oil vaporization. Yang identify the reasons therefore first vaporized measures; such as clogging of the filter circulating pump bypass opening evacuated immediately clean the filter; heat transfer fluid as a result of added aqueous or decomposed gases are not excluded in the system, should immediately open the vent an exhaust valve. Circulation pump pressure constant, the current increases and the flow drops, deterioration of the thermally conductive fluid, the viscosity increased, should be replaced or regenerated. New heat transfer fluid as a result of decomposition of aqueous or excluded gases in the system, should immediately open the vent valve of the exhaust gas. When the current is lower than normal circulation pump, the circulation pump efficiency is decreased, the flow rate decline may be heating pipes plug fouling, stainless steel chain should be cleaned. If the gas steam boiler before and after the filter increased in pressure, the pump inlet pressure drops, the filter may be stuck, the opening of the bypass, disassemble and clean the filter. In addition to its low furnace outlet temperature liquid phase heat carrier, mainly for lack of heat fouling problems, it is timely soot blowing. Gas steam boiler grate more common problem is stuck, there are reasons including breaking grate or the grate off loose pins; coal grate has stuck to metallic inclusions; arched grate; slag is sinking the tip of the grate stuck. In response to this phenomenon, the required reverse hand grate plate debris removal, replacement breaking grate after the start, then jammed as startup, stop the rotation of the reasons detailed inspection to resolve. But also to re-adjust the adjustment screw on both sides of the grate tension, if still does not work, we need to replace the sprocket.

Low nitrogen 5 mw fired industrial boiler and classification of meaning: In recent years, the state vigorously promote clean air plan, Yajian coal. Whether the use of coal-fired central heating boilers, and rural small coal stove for cooking and heating, are gradually being clean energy alternatives under the relevant policy. Thus, in recent years, sulfur dioxide, dust content in the atmosphere continues to decline. But it is worth noting that more and more use of natural gas, also caused a certain amount of nitrogen oxide pollution. Use low nitrogen boiler of the environmental benefits of very large.

Meanwhile, the party also fast 5 mw fired industrial boiler design automation control systems, temperature, pressure, and other parameters automatically adjust the water level, real-time monitoring anti-smoke temperature, oxygen content and changes in safety interlock, even if unattended, the boiler can function . In mid-January 2019, under the fast boiler joint efforts of all staff, boiler manufacturing is completed, the pipeline project has reached Hwashi ground, and successfully complete the installation and commissioning work. At present, the boiler has been put into the urban underground pipeline construction and maintenance projects in order to contribute to building a better city.

What is the difference between the gas 5 mw fired industrial boiler and coal-fired boiler? Whether gas or coal can be used as fuel for boilers, however, named according to the type of fuel used for different boilers are not the same, so there is such a different type of gas boilers and gas boilers. So both types of boilers in addition to the fuel used in the combustion is not the same, between the coal-fired boilers and gas boilers, what difference does it make? 1, fuel is coal flue gas of coal-fired boilers used in different, when coal combustion will have a greater smoke caused serious pollution to the environment, however, high stability of the gas after combustion boiler did not smoke exhaust, because the basic gas on can be completely burned, toxic black smoke can reach zero ringelman level, SO2 content of which is very small, so there is no pollution to the environment. 2, different heat loss in order to allow coal-fired boilers to maintain sufficient combustion efforts require the use of human or other device to stop adding coal-fired furnace, when the need intermittent operation, it takes a long time to start to increase again furnace temperature, it will generate a lot of heat when the pressure of the fire damage, while the gas boiler is very easy to start and stop, fast heating intermittent operation, thereby reducing heat loss in this process. 3, different treatment after burning coal combustion in the boiler will produce large amounts of ash, in order to maintain a good healthy environment need to transport ash to the professional field slag processing, however, gas-fired boiler using gas , there will be no remaining after combustion ash, there is no need to process it, not only to avoid environmental pollution also reduces the labor intensity and the amount of urban ash storage and transportation companies. This is more than some of the differences between the three coal-fired boilers and gas boilers. By introducing the above we can understand the essential difference between the two boilers can understand, it is because of gas boilers more environmentally friendly energy was gradually replace coal-fired boilers. However, if companies need to use this boiler, in order to advance understanding of the security needs of gas-fired boilers which have quality assurance.

Free Chat

About Us

Contact Us