Natural Gas Steam Boiler Dealer

Natural Gas Steam Boiler Dealer

Hot water boiler in the school dormitory and classroom building are generally used for central heating, drinking water and bathing water aspects of teachers and students and so on. Shanxi Linxian County high school is an important educational school personnel training for the community. 2017, the school responded positively to national coal to gas and other environmental policies, but also to provide students with a more favorable living and learning environment, the school decided to phase out conventional coal-fired boilers, clean and environmentally friendly replacement for the gas boiler. After getting to know and choose the boiler industry, major companies, determined cooperation with professional production of clean fuel boiler fast boiler-by-side to provide a fast 4.2MW integrated condensing gas hot water boiler (WNS4.2-1.0 / 115 / 70-YQ).

50, when arranged inside the boiler room to note a safety distance, the front end of the boiler ready spacing of not less than 2/3 of the length of the furnace, and not less than 2 m; vertical boiler can be shortened; bulk boiler is not less than 4 m and does not affect the blast furnace operation and maintenance. 2, the boiler side and rear channel spacing of not less than 0.8 m, and should meet the operational and maintenance (such as replacement tube bundle cleaning, stirring the fire, etc.) requirements. 3, the top horizontal boiler headroom not less than 2 m; vertical boiler top clearance height to facilitate the operation and maintenance; headroom boiler room the other channels, should not be less than 2 meters, when the passage of time and no need to operate its headroom height of 0.7 meters. 4, the boiler room is provided for two or more boilers, the boiler the distance between adjacent not less than 1 to 1.5 times the cylinder diameter of the boiler. 5, the boiler room is generally preferred fireman operation chamber provided, on the total rated greater than or equal evaporation 4t / h steam boiler dealer (heating or hot water boiler is equal to or greater than 2.8MW) must be provided stoker operating room. Electric boiler tank may be provided in front of the boiler, and to ensure the art to fireman facing boiler water gauge, pressure gauge and other instruments during operation. 6, to the total rated evaporation 2t / h fuel gas boiler room to be provided or water spray foam fire extinguisher system, should outdoor outdoor fire hydrant, other fire-fighting equipment should also have the boiler room. 7, the fuel in the boiler room daily oil tank, the oil pump is generally not located in the boiler room, between daily oil tank, the oil pump between the application of the fire resistance of greater than 2.00h wall, the fire resistance of greater than 1.50h floor spaced from the other parts. Daily fuel tank between the boiler room and the door between the oil pump should be able to self-closing fire doors Class A, and let the oil block measures. Household upper tank return pipe to be provided, should be greater than the oil return pipe back to the oil pump. 8, an oil tank and all piping must have a reliable electrostatic grounding, the grounding resistance should not exceed 30 ohms. 9, gas boiler room boiler design should also comply with the relevant safety requirements of gas boiler room.

Gas steam boiler dealer load changes in the water level of air pressure adjustment What happens next: load fluctuation gas steam boiler water level of the air pressure regulating what impact the boiler load refers to the amount of steam is supplied outside?. When the variation amount of steam needed outside world, boiler pressure, temperature, level crossing will move. When the load increases, the pressure drop in the water level is low, the air supply should be increased and the amount of coal. While enhanced combustion, and gradually increase the amount of water to maintain normal air pressure and water level. When reducing the load, the air pressure is high the water level rises, the amount of coal should be reduced and the air volume, reduce combustion, then the appropriate amount of water to reduce or suspend the water supply, the air pressure and water level in the stable nominal range, then press normally combustion and to adjust the amount of water. When reducing the load, the pressure rise when the water level is low, to increase the amount of water should be, until the water level returns to normal, then the need for air pressure changes and the load situation, and to adjust the combustion water.

The working principle of steam boiler dealer steam boiler with boiling water almost equivalent to pot kettle, oven stove equivalent. Boilers and boiler furnaces is divided into two parts, the pot is filled with water to a metal container, partially combusted fuel furnace, the heat absorption of the water inside the pot furnace fuel combustion converted to steam. Popular terms, the steam boiler is to absorb combustion heat of the fuel into the water some parameters (such as pressure, temperature, etc.) of the steam device. For example, everyone knows to pulverized coal, for example. 1. The operation principle (an example in pulverized coal fired boilers) in heat pulverized coal combustion furnace, radiative heat transfer is first absorbed by the water wall, the Wall Boiling water, a large amount of steam into the drum for steam separator (DC furnace excluded), the separated saturated steam enters the superheater, and continues to absorb the furnace top horizontal flue by means of radiation, convection, heat of the flue gas flue of the tail, and the superheated steam to reach the required operating temperature. Power generation boilers are generally provided with a reheater, it is used to heat the steam through the high pressure cylinders acting reheater go out of the reheat steam, the low pressure cylinder to continue to generate power. 2. Pulverized work, the center position of the flame will impact the amount of evaporation, generally, the lower the evaporation flame kernel, the flame kernel high evaporation amount is small; also affects the position of the center of the flame superheated steam or reheat steam temperature, generally lower the center of the flame in particular superheated steam reheat steam temperature to be low, otherwise higher. 3. The arrangement of the burner, pulverized coal fired boiler on, the current embodiment there are opposed wall, more Tangentially combustion, combustion bis Tangentially the like, each have their own characteristics, can not be applied because the same furnace at the same time several above-mentioned arrangement, the steam still can not directly affect the conclusion.

Free Chat

About Us

Contact Us