Hostel Natural Gas Boiler Dealer

Hostel Natural Gas Boiler Dealer

Gas hostel boiler dealer safe handling as the country increasingly stringent emission standards for air pollution, the country has already started work boilers from coal to gas, out of heavily polluting coal-fired boilers, gas boilers using clean fuels. In this regard, Kono Tips boiler, gas boiler process, the need to pay attention to some safety issues: 1. burner to keep the working environment clean and dry, burner cleaning and maintenance once per shift to the control circuit must not get wet, affected by high temperature. 2. Check the electrical installations, mainly: whether the damaged wire, jacket damage, without loosening the screws, the contact is good, the motor is running any abnormal sound. 3. During normal operation, the burner portion close to thermodynamic device (such as a flange connection part) will be very hot, to avoid burns. Do not place near flammable materials, so as not to cause a fire. 4. combustor during startup, if the burner is locked repeated alarm reasons should be identified, and then identify failures and excluded press the reset button (pressing the reset button must not exceed 10 seconds), continue to start. 5. After the total gas pipeline experienced a temporary power failure solenoid valve (steel tile shed) to stop gas supply will automatically shut down until the first call burner electric alarm device to send, then a small hammer solenoid valve with total on hand to pull, you must first send electricity to manually open solenoid valve, solenoid valve will be closed and vice versa total. 6. fireman not mess-tune the burner, abnormal promptly notify management personnel, approved by management and then make adjustments. 7. In the long-term shutdown state, to do maintenance work on the boiler equipment, for each transmission parts to clean, lubricate.

How to pick a good quality energy saving hostel boiler dealer after the Spring Festival, as the footsteps of spring, the weather will be getting warmer, but still occupied Henan sky haze, boiler plant today to explain how to select energy saving boiler? Energy saving boiler how to select, first look at fuel boilers. How to select energy saving boilers, first look at fuel boilers. Fuel gas-fired boiler used as bituminous coal, lignite, coal culprit is called fog and haze, so the gas boiler can not be called environmentally friendly energy-saving boiler. Fuel oil-fired boilers using heavy oil, compared to a gas boiler, has a capacity of environmental protection, but be aware that the boiler blowdown measures, and therefore there is a certain air pollution. Biomass fuel boiler is called energy saving type boiler, the main fuel is a biomass fuel particles, which fuel is free parathion, does not produce sulfur dioxide and phosphorus pentoxide combustion, and thus will not cause acid rain generation, do not pollute air, not pollute the environment, thus greatly easing the greenhouse gas emissions, to purify the air played a very good effect. Therefore, energy saving boiler how to choose? First look at the use of fuel boilers, so according to this aspect, you can determine what type of environmentally friendly energy-saving boiler.

According to the central environmental supervision feedback on the issues raised in item 50: "Mudanjiang 108 wood processing enterprises, 69 there is the issue of illegal construction projects, companies supporting more than 114 hostel boiler dealers for small hand-burning stove, black smoke very serious people to report complaints, "the rectification of the problem. Mudanjiang City, Heilongjiang Province, the municipal government attaches great importance to conduct a comprehensive renovation work for small coal-fired boilers.

The beginning of tasks to carry out, Municipal Environmental Protection Bureau of Mudanjiang City Center 108 existing wood processing enterprises in coal-fired boiler equipment to be checked. Inspection and found 69 illegal construction projects there is a problem, companies supporting more than 114 boilers for small hand-burning stove, black smoke is very serious. To date, there are 65 companies to complete the record, four enterprises waste industry. By Trade and Industry Bureau of Quality Supervision and verification, 114 sets of small boilers of this regulation in the wood enterprises, has completed the transformation units 62, cancellation, revocation 23 units, idle shutdown, waste industry 26, and removal of three. Wherein Yangming boilers zone 97 (where the 58 transformation is complete, the boiler cancellation, revocation table 21, the idle shutdown, industry waste boiler 18); boilers zone 12 (where the grid and transformation of the two, the idle shutdown the six, cancellation of Taiwan, has been demolished three); Dongan District 3 boilers (in which the transformation is complete for two, small boilers cancellation Taiwan); Xi'an area, Edmonton area each in Taiwan, the company has waste industry.

Next, the relevant departments will conscientiously implement the municipal government on Ecological Construction Decision deployment environment, learn from experience and practice fraternal units, work together to tackle, wood enterprises continue to consolidate and expand the results of pollution remediation, pollution prevention and determined to win the battle , to create the sky bluer, more green mountains, clear water and more beautiful environment, Mudanjiang modernization and make due contributions.

You must know the hostel boiler dealer energy problems (induced draft fan power consumption rate, steam consumption) draft fan causes problems 1.1 boiler flue dust and fouling, in particular air preheater fouling, resulting in increased resistance to smoke duct . 1.2 boiler flue, tail heating surface and dust leakage. 1.3 Leakage Rate large air preheater. 1.4 furnace excess air coefficient is too large. 1.5 unit load changes, run the adjustment is not timely, resulting in furnace pressure is too large. 1.6 unit load or low frequent starts and stops. 1.7 coal into the furnace worse, from the design value. 1.8 low efficiency filter. 1.9 draft fan blade badly worn, low operating efficiency. 1.10 fan outlet flue gas desulfurization big resistance. 1.11 soda boiler pipes for leaks. 2, 2.1 to 2.1.1 operational measures to solve the problem of the strict implementation of soot blowing system to prevent the heated area ash, blocking ash, flue gas system to reduce resistance. 2.1.2 holding the induced draft fan, the flue gas separator baffles and dampers in the fully open position. 2.1.3 The experiment showed combustion boiler, proper control of excess air in the furnace. 2.1.4 adjustment chamber negative pressure, air leakage reduction furnace and the flue. 2.2 routine maintenance and testing 2.2.1 induced draft fan performance test to determine the optimum operating point and efficient workspace. 2.2.2 boiler, air preheater, a flue, ESP and other system leakage inspection, process. 2.2.3 timely check processing chassis, shaft seal leakage. 2.3C / D repair, eliminating defects 2.3.1 down strict accordance with movement clearance adjusting fan. 2.3.2 induced draft fan blade defect action elimination hand vane opening adjustment. 2.3.3 Importers and induced draft fan baffle opening check. 2.3.4 duct tightness check process. 2.3.5 wave plate replacement air preheater, rinsed sector plate gap adjustment. 2.3.6 eliminate dust defects and improve collection efficiency. 2.3.7 clean flue gas desulfurization system, flue resistance is reduced. 2.3.8 eliminate soda boiler pipe leakage defects. 2.4A / B repair and transformation 2.4.1 Check and repair the fan blades, replace seriously damaged blades if necessary. 2.4.2 for energy saving fan efficiency below 75%. 2.4.3 The fan motor frequency transformation. 2.4.4 of the precipitator, if necessary, transform and improve collection efficiency.

Free Chat

About Us

Contact Us