10 Ton Gas Fired Hot Water Boiler

10 Ton Gas Fired Hot Water Boiler

Process safety valve check valve gas steam boiler is one of the three safety accessories gas steam boiler, when the boiler pressure is too high, the pressure relief valve will automatically exhaust, gas steam boiler is the important safety equipment . The case of a new installation, overhaul, lack of consumer safety valve shutdown and restart more than three consecutive months, have had to re-check safety valve, safety valve to ensure accurate and reliable by the company safety officer, boiler technician, run operators, maintenance personnel together with the completion of the adjustment. Valve adjustment procedure is as follows: 1, the steam boiler when the gas vapor pressure close to the operating pressure of the safety valve, and retest check valve to the air motor exhaust, drainage accident flexibility and reliability of the electric valve, and the panel reinspection situ pressure gauge, the water level of accuracy, such as failure, not allowed to heat the school. 2, ready to call and check the quality of communication tools, a signal indicating whether the good. 3, adjust the safety valves, boiler pressure should be kept stable, pay attention to monitoring gas steam boiler drum level, and maintain normal. 4, steam boiler safety valve to adjust the pressure gauge in place of instructions shall prevail. If necessary using 0.4 or more for the accuracy of the gauge. 5, adjust the safety valve should be carried out only by descending. It should checksum gas steam boiler tuning high pressure safety valve, after the school seizure of the entire set of low pressure relief valve. 6, the following should be in the 0.3MPa, the movement preventing measures must do a good job of setting relatively low pressure steam boiler safety valve safety valve before adjusting. 7, by combustion, and exhaust steam adjust the degree of opening to the air slowly and smoothly up to the required setting pressure. 8, when the gas pressure steam boiler safety valve set pressure to rise if action is normal, then the action and reseating pressure values ​​recorded. If action is not correct or not action should be immediately opened to the air exhaust valve, while the combustion boiler weakened, stop boost, and buck 0.3MPa or less, re-adjust the boiler technician as required by maintenance personnel, until the compliance date. (Lead or lag 0.05MPa action is normal). 9, after the completion valve to adjust gas steam boiler, boiler 0.3MPa or less down to the lifting device and can be installed and fastened to the protective cover, a braking measure required under check valve removal, then Articles 7, 8 verify until all required safety valve calibration check is completed. 10, the safety valve to adjust the gas boiler, check the results recorded in the "safety valve to adjust the recording Visa" within the participants should verify the signatures and Internet safety valve input to the corresponding data in the ledger. During operation gas steam boiler, not only to regularly check on the safety valve, at the same time, we must regularly monitor boiler inspection to ensure that the boiler fully meet the safety requirements!

WNS type gas steam boiler system control principle: ①, after WNS type gas steam boiler on the power switch, click on the pump control switch open position, after boiler feed water rises to the normal position, click-burner power switch, clicking the start button, the control system power is on, the burner into the working state, according to the operation program for the controller, to be re-ignition burner fires into the combustion state, the boiler enters normal operation this stage. ②, high output level when the water level rose to a high level alarm signal indicator light, when the water level rises to the pump stops running + 25mm, the water pump when the water level falls -25mmm automatic restart, when the water level falls -50mm, outputs a low level alarm indicator light, with bell sound, and cut off the power to the controller to achieve protection shutdown, -75 mm when the water level falls, the output signal of low water level indicator light. ③, when the pressure is raised 0.73MPa, the output signal of the first indicator light overpressure, combustion conditions and off the controller circuit, the controller stops the shutdown. Output when the pressure rises above a second overpressure 0.75MPa signal issued bell sound, alarm and cut off the power supply control system implemented emergency stop. Regulating the pressure when the pressure exceeds the upper limit, the controller output signal of a small fire fire closed valve, a valve to open the small kerosene ignition burner. When the lower limit pressure drops below the regulated pressure, the controller outputs the fire signal to open fuel valve fire, the fire to burn. ④, after the failure of the burner failure occurs, the burner control valve is automatically shut down to stop the oil combustion. Vertical coal-fired steam boiler structural features

Hefei Limin Pharmaceutical Co., Ltd. Nanjing Military Region, formerly the backbone of pharmaceutical companies, the main drug is slowly swallow rather teabag, relying on advanced R & D platform to carry out contract manufacturing, OEM OEM and other business cooperation. China's environmental protection development trend began to take shape, many environmental policies have been put forward for a positive response to the national environmental policy, Limin Pharmaceutical decided to introduce a gas station steam boilers. After an investigation of the boiler market, Limin Pharmaceutical fast boiler is strong comprehensive strength and wealth of experience working for many years in the pharmaceutical industry to attract, party fast according to the actual needs of customers for its recommendation of one of Taiwan 4 tons of steam condensate gas-fired steam boiler (WNS4-1.25-YQ).

Steam boilers What is the function? Too many in the form of steam boilers, would like to give a quick four tons of ordinary steam boiler talk. Water in the steam drum is heated to become vapor, fire emits heat in the furnace, it is the principle of the steam boiler. Let me say a boiler pot. This boiler is a boiler drum with a water cooling wall at about the subregional arrangements drum pyrotechnic two return pipe, before the folded portion of the drum front smoke box. Between the drum and the tank in connection with the downcomer tubes and water-cooled bi, constituting the frame of the combustion chamber. There upper steam separator drum to reduce the water vapor out of the tape. Pan heating surface of a lower portion of the drum, and the water cooling pipe bi pyrotechnic tube. A chain grate combustion section and drive means, coupled with the combustion chamber pan rack on the frame configuration composed of the grate. Four weeks envelope refractories. . From coal fired into the hopper, the shutter coal front portion while sealing air control seam thickness. Blast into the lower part of the combustion chamber is a place that boiler greater resistance, need to force the blast. Cinder burn out, through the grate in the rear portion of the olecranon iron discharged from the machine to send out of the furnace slag. The boiler flue gas from the rear, by the front drum smoke tube a return line, the return from the two rear return smoke tube, and then into the dust separating ashes, and then discharged through the chimney draft fan. Not only is the induced draft fan exhaust fumes, the negative pressure of the boiler operation is required. Steam boiler pressure vessels, safety devices is necessary. Boiler necessary water level gauge, pressure gauge, safety valve, thermometer, and under the pressure of the electric pump can pay, and the vapor pump when power is off can also be used. Boiler water must be softened, as well as water treatment equipment.

Free Chat

About Us

Contact Us