Natural Gas Boiler Heating Area

Natural Gas Boiler Heating Area

What shall we do after the fuel (gas) boiler heating area is put out? In front of the burning oil and gas boiler manufacturer-gas-fired Fangkuai boiler, introduced "burning oil-gas boiler extinguished after the state is what?", there are a lot of users called to consult, once the extinguishment should be dealt with correctly, can reduce the loss?

A few months ago, Shandong Provincial People's Government issued the "Opinions on Further expand domestic demand and promote development of up short board", which refers to: As of 2020, invested 11 million yuan to complete 5.4 million renovation to replace it clean, let 55 % of villages to achieve clean heating.

In the "clean warm winter Shandong Province Planning (2018-2022 years)" is mentioned, in 2020 the provincial average clean heating rate of 70%, of which more than 20 million people in the city basically clean heating full coverage. 2022, the province's clean heating rate of over 80%. Among them, more than the city and county basically clean heating full coverage, the average clean heating in rural areas reached about 75%.

Jinan, Qingdao, Yantai City 3 converts kinetic energy as a province of old and new core area, to take the lead in forming an electrical heating alternatives such as clean coal-fired heating San basic pattern. Should be in accordance with the electrical power, should be renewable energy sources of renewable energy, the principle of the dispersed phase concentration and binding, while the priority of central heating, the positive development of other energy sources for heating air.

Differences and characteristics of vertical and horizontal industrial boiler heating areas industrial boilers? With respect to the vertical boiler, many customers are more inclined to horizontal boiler, and why? In large part because all that space boiler room. Another reason is the customer's misunderstanding that is long sideways horizontal boiler, is standing vertical boiler, for example, many customers believe that large-scale bulk fluidized bed boiler is vertical, but for this boiler, the and no vertical or horizontal points. Boiler industry-specific vertical and horizontal boiler boiler two words, speaking from the model, such as gas-fired boiler fuel WNS is horizontal, that is, "W" of the content, which is a horizontal furnace oil and gas products; standing the boiler is LSG vertical "L" of pressure boilers.

Method of reducing the exhaust gas temperature of the boiler heating area which: standard boiler exhaust gas temperature: between the boiler flue gas temperature of 200-230 deg.] C in accordance with conventional design national standard thermodynamic calculation boiler design requirements. Conventional exhaust gas temperature selected reasons, coal fired boiler combustion process will produce a certain amount of SO2, and SO2 below 170 ℃ will bind and generating flue gas H2O H2SO4 sulfuric acid, H2SO4 sulfuric acid and will form boiler heating surface of tail corrosion, thereby reducing the life of the boiler, conventional coal-fired boiler exhaust gas temperature is higher than 200 ℃. Temperature is high energy loss and more, is not conducive to energy saving. Cooling measures taken to ①, the economizer application: increasing the boiler economizer (economizer) of heat transfer area, larger than the conventional take about 1-2 times the flow cross sectional area economizer structure, effectively reduce smoke flow rate, to strengthen the heat transfer efficiency, reduce exhaust gas temperature; ②, air preheater applications: pipes connected to the air preheater economizer disposed, the apparatus can effectively increase the temperature of the combustion air, improving the ignition of the fuel condition. Very beneficial to the boiler combustion conditions. ③, adjust bidirectionality combustion system, a boiler originally designed for fuel specifications have some flexibility, different media in effect outside the combustion process are different, adjusting the embodiment, with the economizer and the air preheater using, the temperature of the boiler exhaust emission control at a suitable temperature, that make full use of heat energy, but also to ensure the integrity of the structure and function of the relative equipment, environmental protection, energy saving, security and development is the social responsibility of all of us for a rational design of industrial structure boiler, thermal efficiency is relatively high, its emissions would be relatively low temperatures, so we must be careful when choosing a boiler boiler property report form.

Free Chat

About Us

Contact Us