What Kind Of Gas Use In Boiler

What Kind Of Gas Use In Boiler

Combustion conditions provides rapid and substantially complete combustion of 1, a relatively high furnace temperature: the chemical reaction is the basic condition of combustion, fuel ignition and stable combustion, burn have a significant impact, maintaining a suitably high temperature furnace to important. Of course, when the furnace temperature is too high, consider the problem of slagging what kind of use in boilers. 2, the air supply amount: the amount of air supply, is to provide enough oxygen for the fuel, which is the original conditions of the combustion reaction. Air supply, fuel not get enough oxygen, it can not achieve complete combustion. But excessive air, the furnace temperature will lead to loss and exhaust loss increases. 3, good mixing conditions: Mixing is an important physical conditions of the combustion reaction. Mixing the hot flue gas in the furnace is heated to reflux of the pulverized coal flow, so as to rapidly fire. Mixing in the furnace is strongly perturbed stream to provide oxygen to the soot combustion stage surface, outward diffusion of carbon dioxide, and to promote post-combustion of the fuel burn, it is an indispensable condition. 4, enough burn time: the fuel in the furnace for a time sufficient to achieve a high degree of fuel burn, which requires a large enough volume of the furnace. Proportional to the volume of the furnace and boiler capacity. Of course, the furnace volume is also characteristics of the fuel combustion, easy to burn fuel, furnace volume can be relatively small. For example, the same capacity of the boiler, furnace volume of fuel than pulverized coal furnace is small, and vanished without burning furnace volume than coal burning bituminous coal furnace volume slightly larger.

Inter-regional Pingdingshan Coal Industry Group Co., Ltd. by the Pingdingshan Shenma Group and two Chinese top 500 enterprises founded by restructuring, cross-industry, cross-ownership and transnational business of large state-owned energy and chemical group, under the People's Government of Henan Province , is the most complete variety of coking coal, thermal coal production base, has Asia's largest chemical production base in nylon. Carefully selected and comparison, fast what kind of use in boiler Pingmei cooperation with party has chosen to provide a 2 tons of steam electric steam boiler (WDR2.0-1.25-II) by a fast side.

Coal-fired what kind of use in boilers to gas boilers benefits and precautions With the rapid development of national energy-saving environmental protection, the traditional coal-fired boiler can not meet the needs of the times. Therefore, the coal-fired boiler biomass boiler or gas boiler has become in many boiler user's choice. Before the transformation, to understand the difference between .1 and gas boiler fired boiler. Circulating fluidized bed combustion boiler fired by coal crushing device fluidized combustion process, the coal by crushing device percutaneously into the bunker through a the spreading coal coal injecting air into the furnace; circulating ash by heating, fluidized combustion process. When the coal into a gas fuel is injected directly into the combustor for combustion. 2. Combustion of Coal is mainly composed of C, H, O, N, S, ash and moisture and other elements. Generated when coal SO2, SO3, NOx ash and moisture, and SO2, SO3, NOx from flue gas emitted into the atmosphere, pollute the environment and cause harm to humans. The main components of the exhaust gas and coke are CO and H2. The main produce CO2 and H2 post-combustion, much lower than coal-fired boiler SO2, SO3 and NOX emissions. 3. Ventilation pressurized combustion coal combustion boiler used in a combustion mode. The bottom of the combustion process through the induced draft fan with fan and completed. In the combustion of coal, it requires a lot of air. Gas under a slight positive pressure in the boiler or burner slightly negative pressure, which requires less airflow. Burner air may be pre-mixed with natural gas. 4. coal boiler control reasons, material thickness, amount of wind, the wind volume, wind and other than coal, coal-fired boiler is difficult to automatically adjust the operating parameters of the boiler according to the load. However, fewer factors gas boiler, the burner valve can be adjusted according to the size of the load, easy to implement automatic control. Coal-fired boiler to a gas boiler Notes: Main results are as follows: (1) small boiler, the coal-fired boiler to a gas boiler, i.e. the negative pressure of combustion from the original to the current combustion slight positive pressure, and must pay attention to the furnace wall structure sealing problems. Closely related (2) selection and arrangement of the burner and furnace, the degree of filling of the flame in the furnace is preferably not formed dead air, to avoid the interference of adjacent flame burners, to avoid interference from adjacent burner flame. Unburned gas - air mixture should not be in contact with a heated surface, in order to avoid incomplete combustion. Gas combustion. Gas burner arrangement disposed conduit and ducts should be considered reasonable gas pipe and duct arrangement, ease of operation, inspection and maintenance. (3) the transformation of coal-fired boilers is mechanized layered gas boiler should be removed before the arch and the arch, and the bottom heating surface increases, in place of the grate, the grate to prevent overheating. Gas Velocity (4) on heat transfer surface of the fly ash is not restricted abrasion conditions, convection heating surface heat transfer coefficient is increased, increasing the pressure in the boiler where H is unduly increased. Boiler erosion surface. At this time, the capacity of the boiler should be noted that the steam separator to ensure the quality of the steam.

With the increase of air supply volume, the mixture of oil mist and air is improved, which is beneficial to combustion. However, if the air volume is too large, the furnace temperature will be decreased and the incomplete combustion loss will be increased. At the same time, the heat loss of exhaust gas will be increased and the power consumption of the fan will be increased because of the increase of flue gas. If the air volume is insufficient, the combustion will be incomplete, resulting in carbon deposition at the tail, which is prone to secondary combustion accidents. Therefore, each what kind of use in boiler should pass the thermal efficiency test to determine its economic air volume at different loads. In practice, the stoves usually take into account the ignition of the nozzle and the carbon dioxide or oxygen content in the flue gas. Content to adjust the supply air volume. If it is found that the combustion condition of a nozzle is not good, or if the atomization plate with different aperture is replaced, the air pressure of the supply duct should be kept unchanged, and the opening degree of the duct baffle of the nozzle should be adjusted to normal combustion. If the fuel quantity changes due to the change of the oil pressure in front of the furnace, the opening of the fan baffle should be adjusted to achieve normal combustion by changing the air pressure and air volume of the air supply duct when it is necessary to adjust the supply air volume.

3) the observation and analysis of all kinds of flame when adjusting the fuel oil. Generally through the fire point adjustment and flame center adjustment to complete the flame adjustment. The ignition point of the oil mist should be close to the nozzle, but there should be no tempering. Early ignition is beneficial to complete combustion and stability of oil mist. However, the fire is too early, too close to the nozzle, easy to burn the nozzle and furnace wall to determine the mouth. Furnace temperature flying oil varieties and atomization quality, as well as air volume, wind speed and oil temperature, will affect the distance and proximity of the ignition point. So if you want to adjust the ignition point, you should find out the cause in advance, and then take targeted measures. When the boiler load is constant and the oil pressure and oil temperature are stable, Should be based on the ignition point wind speed and wind distribution situation.

Free Chat

About Us

Contact Us