Bath Center Gas Water Boiler

Bath Center Gas Water Boiler

Features gas steam boiler are: energy saving and easy to install biomass boilers is a kind of boiler is used as boiler fuel to biomass energy is called biomass boilers, steam boilers into biomass, biomass hot bath center water boiler, biomass stove, biomass gas steam boiler, biomass boiler vertical, horizontal biomass boilers. ---- boiler combustion apparatus most suitable for reciprocating grate biomass fuel combustion. Boiler structural design, relatively large conventional boiler furnace space, while the secondary air is arranged very reasonable, precipitated instantly when favor combustion of raw material a large amount of volatile fuel combustion. Boiler can be equipped with fuel (gas) ignition burner ignition achieve automation. Boiler feed, combustion, slag, water supply, ignition can be automatically controlled, the operation is very convenient. The boiler is equipped with an automatic cleaning device, can timely removal of the boiler heating surface fouling, boiler to ensure efficient and stable operation. Rear of the boiler economizer disposed, you may need to be arranged according to the air preheater user. Compared with the traditional boiler higher boiler efficiency, low exhaust gas temperature. Efficient insulation material, the surface temperature of the boiler is low, the heat loss is negligible. China strictly in accordance with national norms and standards, all boiler pressure parts are made of high quality steel. Before each boiler factory to go through a rigorous inspection and testing, including pressure testing and X-ray detection. Set manhole, inspection doors, fire observation holes, etc., maintenance is very convenient. Features biomass boilers are: energy saving, environmental protection, and easy to install.

Subsequently, the delegation visited the company's boiler cleaning laboratory, technicians demonstrated to the delegation of the company's latest product boiler operation, and use of DCS control system in the laboratory trace data. Mr. Liu to our boiler products to achieve nitrogen oxide (referred to as NOx) emissions below 18 mg or less, is widely used in Beijing APEC venue, the Central Authority and other countries prefix institutions and other international occasions expressed a high degree of praise and encourage.

Gas boiler room location should pay attention to these issues need to pay attention to the location of gas boiler room boiler room of a problem than how specific to the site, more customers just curious boiler room and other buildings safe distance, do have customers believe boiler room just fills the room, as long as the boiler plant went on line, do not need to sun and rain. But in fact, the boiler room location is very important, it is related to a series of questions of your initial investment and system planning, job handling and safety protection. With gas boiler, for example, for us to introduce issues related to pay attention to the orientation of the boiler room. 1, the orientation of the gas boiler room should be summarized gas type, boiler capacity, operating pressure, supply and return water temperature, the system in the form of building types and other factors to consider. 2, natural gas boiler room planning should be "boiler room planning norms" (GB50041-2008), "town gas planning norms" (GB50028-2006), "building plans for fire protection" (GB50016-2006), "the senior civilian in accordance with existing national norms architectural plans for fire protection "(GB50045-95) (2005), and" hot bath center water boiler safety skills supervision "(labor pan word [1997] No. 7) are summarized concluded. If there are local with local codes, with the satisfaction to consider. 3, gas boiler room should be set in separate buildings on the ground, if the conditions are bound, connected to the main building or need to set up in the basement of the main building, semi-basement, while the first floor, the top floor and center floor, shall be approved by the local fire, safety supervision and environmental protection part of the agreement. 4, gas boiler room directly prohibit people gathered in the room (such as public baths, classrooms, auditoriums, shops, restaurants, waiting rooms, etc.) or at the top, bottom, or top lax immediate neighborhood of the mouth on both sides. 5, the new residence should not be connected to the boiler room, boiler room and other adjacent buildings, the wall adjacent to the firewall. Boiler room on the ground should be flat without steps, and should prevent accumulation of water. 6, because the conditions there are shackles, located in the basement boiler need, center or top floor high-rise buildings or multi-layer, prior consent of the city, prefecture-level and above safety watchdog agree. In addition to the above requirements satisfaction, it should also be satisfied: (1) each boiler rated evaporation does not exceed 4t / h, the vapor pressure does not exceed the rated 1.6MPa. (2) oil is necessary, as a fuel gas or electric heating boiler. (3) the fuel supply line adapter using welding backing. 7, as provided in the boiler room in the basement or the first half-layer or multi-layer high-rise buildings, it is necessary to fit together the following conditions: (1) each boiler rated evaporation does not exceed 10t / h, the vapor pressure does not exceed the rated 1.6MPa. (2) Each boiler necessary to have reliable overpressure protection device interlock and interlock the bottom level protection. (3) accessories and safety interlock protection device for each boiler to regular maintenance and experiments to ensure active, reliable. (4) the building structure between the boiler should be the appropriate seismic measures. (5) operating independently fireman fireman operating permits necessary to hold the appropriate level of boiler and continuous operation of the same class more than five years, has not had trouble occurs. (6) the need to have lax security channel.

Coal-fired steam boiler auxiliary equipment which is the result of burning coal-fired steam boiler fuel coal fired boilers to provide steam for industrial production, with the rapid development of the national industrial production, market demand for coal-fired steam boiler gradually increased, boiler in addition to the main components, further include other auxiliary devices, such as coal feeder, induced draft fan and the like. As a supporting auxiliary equipment coal-fired steam boilers, related to an important indicator of whether the normal operation of the boiler, auxiliary equipment and its role following is a small series of analyzes and summarizes the coal-fired steam boiler: 1, fuel supply equipment: Storage and transportation fuels. 2, coal grinding and milling equipment: Pulverized coal milled to a pulverized coal burning and enter the combustion boiler combustion apparatus. 3, the wind blowing apparatus: the air blowing device is defined by the air into the blower means exports coal furnace air preheater after heating and milling. Blower device refers to the boiler flue gas discharged from the chimney draft fan and sent to atmosphere. 4, water supply equipment: water through the water treatment device processing into fired steam from the feed pump. 5, slag, dust removal equipment: Cleaner Equipment refers to the removal of ash from the boiler and carry away equipment, dust removal equipment refers to the removal of fly ash in the boiler flue gas, improved sanitation. 6, the automatic control device: automatic detection, process control, automatic protection and automatic adjustment. Advanced coal-fired steam boiler in a programmable logic controller (PLC) is the central processor of the control system. The control system via the touch screen operation, the boiler automatic control and degree of operational reliability is greatly improved, easier to use and intuitive.

Free Chat

About Us

Contact Us