Electric high efficient steam boiler combustion efficiency and how to save more: In China container industry is a growing industry, and container industries and enterprises are also faced with various challenges. Container industry must adhere to market-oriented strategy, closely rely on scientific and technological progress, scientific and technological innovation, under the guidance of national energy and environmental policy, company structure and product structure adjustment, manufacture and sale of container in line with market demand, occupancy in the fierce competition in the market place. Electric steam boiler to improve the combustion efficiency, saving fuel, the fuel quality should be controlled, uniform atomization burner. To achieve the above object, the following points should be noted: 1 to understand the combustion principle, adjusting the wind ratio of positive oil (gas), to achieve efficient combustion; 2, to maintain a good working condition of the nozzle, the nozzle is not easy too large or too small, the nozzle wear obstruction, carbon status, to ensure good atomization combustion conditions. 3, to maintain proper pressure or hydraulic, pneumatic or steam boilers, such as high or low oil pressure, and a hydraulic or pneumatic pressure is too large or too small, will affect the mixing of fuel and air uniformly. 4, to adjust the burner flame length brains spray angle size and shape of the combustion chamber with fire furnace chamber filled eye, achieve economic combustion. No black smoke, no soot, in the good sense of the coming year running.

Sales Director shared the 2017 summary of the work group marketing and marketing strategy in the 2018 General Assembly. 2018, the party will continue to move forward faster, increase marketing efforts, new product development efforts, service brand strength and marketing penetration efforts, multifaceted promotion, fully operational.

The main reason gas high efficient steam boiler produces smoke which fuel gas steam boiler main cause of smoke. A fuel gas steam boiler: oil, gas oil quality is not good when the gas contains more water, reduce the heat value of the fuel, while producing steam, the furnace temperature tends to decrease, making it difficult to burn, easy to produce smoke. Water and more oil, mainly when unloading rain water into the oil during heating the oil in water vapor penetration. When the oil contains impurities, the impurities unburned produce fine coke, the coke into fine smoke, dust becomes large, and the formation of soot. Impurities contained in the oil and gas, but also affect the pure oil and pure combustion gas generated soot. Oil impurities, mainly due to inappropriate choice of filters or filter difference impurity removal effect. Second, the failure of the fuel atomizing nozzle member main burner fuel oil atomizing nozzle. Atomizing oil burner nozzle fails, affecting the quality of the atomization, easy to poor combustion. 1, the adhesiveness between the bonding surface of the oil and the consequences of failure oil atomizers swirl atomizers and the splitter plate well, leakage will occur, atomized large oil particles, increasing the amount of fuel injection and the like. In this case serious deterioration of the quality of the combustion, the oil droplets have landed on the water wall, stacking up oil coke, partially unburned black smoke into droplets. The tangential swirl chip groove clogging mist causes uneven density distribution in the dense side of the oil mist, combustion air be insufficient. In the more dilute side of the oil mist, combustion air causes severe local excess. Mixed with oil, wind conditions deteriorated significantly, combustion conditions deteriorate, resulting in black smoke. 2, spray atomization slice failure and the consequences of failure to clogging and wear. Nozzle clogging, resulting in blockage of the fuel injection quantity is not glib increase, oil particle size thicker, the effect of fuel poor and black smoke. Wear injection port, a large hole diameter, increasing the amount of fuel injection, increasing the particle size of oil affect combustion efficiency, produce black smoke. The use of artificial gas burner, naphthalene and tar and other impurities will block the nozzles, the influence of gas distribution, resulting in black smoke. Should therefore be cleaned regularly, or clogging of the selected burner. 3, the partition partitioning poor poor, insufficient supply of air into and excess. The amount of air can not meet the requirements of the fuel combustion, so that combustion of fuel can not be sufficiently black smoke. The amount of air, will result in lower combustion temperature, black smoke and fuel difficult to burn. 4, the furnace temperature is too low when starting the furnace, fuel oil steam boiler furnace temperature is too low due to easy black smoke. 5, the furnace hearth product oil is sometimes caused by internal combustion nozzle oil accumulated inside the chamber, the oil reservoir coke black smoke at high temperature. Causes dripping of fuel combustion nozzle: ① The drip just work, just at the operating pressure is too low, the oil will flow from the nozzle, instead of the discharge. The reason for low oil pressure is a solenoid valve, the valve is clogged filter or the like or failure caused by contamination. ② In the dripping process work, probably because the relative position of burner nozzle mounting head too far, improper ignition electrode position, the oil into the atomizer, the nozzle holder is mounted is not tight, nozzle dirty, low oil pressure caused. ③ When the dripping stopped, because the line between the pump and the air nozzle, electromagnetic valve or a hydraulic valve or dirty failure. 6, the furnace flue purged countless consequences when the furnace flue remnants of oil and gas, when gas purging endless, high temperatures encountered in the explosion and black smoke. 7, the furnace smoke, sparks, the furnace pressure is too ①; ② inappropriate choice of the burner, the burner flame is too long or too much power; ③ improper combustion ratio, there are more to produce products of incomplete combustion; ④ atomization quality is not good nozzle or improper installation location, or affect the combustion flame into the furnace off port; ⑤ flue is blocked, poor smoke; ⑥ a secondary air mismatches; irrational ⑦ furnace structure; ⑧ oil spray angle is selected from with improper.

Gas-fired high efficient steam boiler equipment maintenance equipment maintenance points 1: 1, or twice a day to clean up slag. 2, washed once or twice a heater dust (ash door with the appliance design) weekly. 3, once or twice a month, or butter oil feeding helical gears and bearings induced draft fan. 4, a monthly injection of butter or oil to the fan motor bearings once or twice. 5, a boiler must be 2-4 times the annual emissions (emissions must promptly after filling water). 6, poor water quality, in use. 2. Before, must soften water. Gas hot water boiler with environmental protection, energy conservation, safety, salient features fully automatic operation, and ease of use. In addition, due to the operation of the economy, government policies to encourage, gas hot water boiler more and more people of all ages. Daily inspection equipment: 1, the fan regularly checks whether there is a feed screw loosening device, whether there is abnormal noise. 2, regular inspection trip tank float valve is normal replenishment, water pressure is normal. Biomass boiler categories: biomass boilers Horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass steam boiler, biomass hot water boiler, biomass oil furnace. 3, if equipped with a pump, replace circulation pump on a regular basis, and check whether the pump is working properly. Function gas boiler the ignition system that ignites the mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas boiler manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. 4, regular inspection equipment grounding cable is connected correctly. 5, to ensure the normal supply of fuel in the hopper, so as to avoid non-fuel flameout downtime. 6, it should be observed regularly combustion of the fuel in the combustion chamber. Incomplete combustion of fuel, smoke or large block to form sulfur, the sulfur should be promptly removed block and the governor to adjust the feed flow rate ratio of the fan, to achieve the desired combustion.

Free Chat

About Us

Contact Us