Oil Fired Steam Boiler Textile Industry

Oil Fired Steam Boiler Textile Industry

Gas introduced gas fired steam boiler textile industry steam boiler stop sign Profile: natural gas steam boiler is a steam boiler gas, natural gas steam boiler with natural gas as fuel, the combustion in the furnace heat put out by heating the pot water, and allowed to vaporized into steam energy conversion device. Water pan (drum) is continuously released from the combustion of a gaseous fuel energy to heat the furnace temperature is increased and produce steam under pressure. Since the boiling point of water increases with increased pressure, the pot is sealed, the expansion of water vapor generated inside the pressure limited thermodynamic formed, strictly speaking, the steam boiler is heated in water at constant pressure saturated steam drum regasification water formed, is widely used as an energy source. Protection device: (1) protect the boiler water a boiler water level gauge plate supporting one to two, should always be compared with each other, inconsistent findings indicate that shall be corrected immediately. Class water level should be flushed, to determine their true level. While the water level comes electrode rod can accurately capture level signal to an alarm or a pump control. (2) steam pressure protection pressure controller: selection of high sensitivity of the pressure controller, the pressure is high, or low levels of signal to the electrical switches, other control lines or automatic control chain protection. Using pressure controllers and electrical contacts, the vapor pressure can overpressure alarm; single adjustable pressure controller or dual fire burning fire the actual operating pressure. Safety valve: safety valve is the last line of defense to protect the boiler, the boiler pressure exceeds the limit, according to the set pressure relief valve design with the school, the exhaust steam pressure relief, to ensure the normal operation of the boiler. (3) having a burner flame protection flame protection inlet means, combustion function is to detect, when the ignition failure or extinguish combustion middle, immediately off the burner into the oil (gas) solenoid valve, the blower continues to operate at this time, the furnace was purged combustible residual gas, after 20 to 30 seconds purge, and various auxiliary blowers automatically cut off power, the boiler operation stops. (4) self-locking power failure protection case, the boiler shutdown immediately burst self-locking power interruption, if the current power is restored, the boiler will not start at any time, you must reset release self-locking, to re-start the ignition. Editing boiler ignition procedures: 1. Check operation and (or) shift recording. 2, inspection, examination boiler, external. 3, check the main safety accessories. Safety valve, water gauge, pressure gauge, to be tight, reliable and sensitive. 4, check the water treatment equipment. 5, inspection equipment and soda water supply system pipe. Adjust the valves as required to start. 6. Check the oil supply equipment. After the above inspection qualified, you can start the boiler. Note: The boiler is a high-temperature, high-pressure thermal equipment, is one of special equipment, widely used in government agencies, public companies and all walks of life, it is dangerous and special equipment. Event of an accident involving public safety, it will cause huge losses to the state and people's lives and property. For public safety, people's lives and property safety, according to the State Council, "Regulations on Safety Supervision of Special Equipment", the boiler should use full attention the following matters: 1, should be accompanied by safety technical specifications of the factory boiler design documents, product quality certification, safety and the use and maintenance instructions, supervision and inspection certificate (safety supervision, inspection and performance certificate). 2, boiler installation, maintenance, alteration. Engaged in the installation of the boiler, maintenance, renovation of the unit shall obtain special equipment installation and maintenance certificates issued by the Provincial Quality and Technical Supervision, before engaging in the boiler installation, maintenance, alteration. Construction unit before construction will be prepared for installation, maintenance, alteration in writing inform the special equipment safety supervision and management department of the municipality or district, and will start informing sent to the local county level Quality and Technical Supervision for the record, told immediately after construction. 3, inspection of boiler installation, maintenance, transformation. After construction, the construction unit To State Quality and Technical Supervision of Special Equipment Inspection and hydrostatic testing of the boiler installation supervisory inspection declaration. After passing by the State Quality and Technical Supervision, State Special Equipment Inspection, County of Quality and Technical Supervision involved in overall acceptance. 4, registration boiler. After the boiler inspection, the use of units must be in accordance with the "special equipment registration and use of management rules", fill "boiler (census) Registration Form", the State Quality and Technical Supervision to register and obtain a "registration certificate to use special equipment safety . " 5, operation of the boiler. Boiler operation must be performed by trained and qualified to obtain "special equipment operator certificate" certified personnel to operate, must strictly abide by the rules and eight systems, six record. 6, check the boiler. Periodic inspection of boiler once a year, not be used without safety periodic inspection of boilers. Safety accessories safety valve of the boiler regular inspection once a year, pressure gauge biannually verified, may not be used without the periodic inspection of the safety accessories. 7, non-pressure boilers will be installed for the boiler pressure. Do not use water level gauge, safety valve, pressure gauge three safety accessories insufficiency boiler.

Solutions and prevention of gas oil-fired boiler flameout Today we'll resolve what about gas fuel boiler flameout solutions and prevention fuel gas-fired boiler flameout Solution: First, the furnace pressure gauge indicates the value suddenly increases, the furnace black can not see the flame, burning furnace sounds disappear, extinguishing the flame supervision devices emit a signal; the temperature dropped sharply atmospheric pressure, the water level dropped after the first rise, and so are flameout phenomenon. Auxiliary flame caused by an accident, such as a fan, blower power interruption, there is an accident signal emitted; fuel supply as a result of intermittent, the boiler is oil or gas pressure drops to zero, only a single burner flame, the furnace may also be thrown skew central flame extinguished burner pressure change; as a result of the fuel supply interruption, the extinguished burner pressure or hydraulic indication may drop to zero, and the fuel consumption, the gas pressure is increased other operating burner. Causes gas boiler flameout are: sudden increase in gas pressure caused from the fire, the solenoid valve malfunction the gas supply interruption, the gas composition has changed so much moisture content is too high and so on. Blower, fan failure, the load is too low furnace pressure is too large excessive leakage and other excessive wind, so that the furnace temperature is too low can also cause the boiler flame. Cause misfire has oil-fired boiler: oil pump failure, the oil surface is exposed inhalation tube, clogging of the oil filter or oil supply pipe, a solenoid valve malfunction or misoperation caused by oil running intermittently. During transport the fuel with steam by heating water; inappropriate position inhalation tube with the pumping of water; improper contaminated oil floating on the water; poor dewatering tank drain plug such that the fuel with water. After the explosion should be taken to prevent the furnace boiler flameout, it must immediately cut off the fuel supply to the furnace, and then block the electromagnetic valve of the gas supply valve to seal off the fuel supply to run the burner. When the action to be fast in order to avoid inheritance or restore fuel supply during operation, causing the furnace explosion. And identify the cause of boiler flameout troubleshooting find a good job and then start the preparatory work. Before starting the boiler should be enhanced ventilation purge, purge time is more than 5min, then procedures ignition. It is forbidden to send fuel directly to the high-temperature furnace without using an ignition spark ignition device to prevent furnace explosions. If due to fan failure caused when the flame should be quickly cordoned off the fuel supply line of each valve, with special attention because the valve is not tight blockade caused by leaking fuel. Ventilation and purging of the furnace and flue in accordance with the approach of an emergency shutdown. Ignition step by step in the recovery operation after the fan. Single burner flame burner only block the fuel supply valve, the burner off a small damper identifying and troubleshooting and then re-ignition by the ignition process. Boiler flameout of prevention: For oil-fired boiler should minimize the possibility of fuel transport, storage and handling of water in all sectors. Tank initiative measures should dehydration and dehydration on schedule. In any case, it should ensure the security of oil supply. The supply of oil and acceptance testing, cutting oil change when the master species. When a large change in oil types, varieties and the need for the oil tank to store the original varieties contaminated test to determine whether the same storage tank, to prevent the density and viscosity differences between a large number of decomposed oil mixed insoluble material, clogging oil pipeline. For the operation of the gas boiler should be closely monitoring the evolution of gas pressure, the timely processing of exceptions thrown up air pressure, ensure the supply pressure in the normal range. To always understand, repair gas composition, gas composition changes when large, to take the necessary adjustment measures on the boiler operation.

Burns Hospital Affiliated Hospital of Shanxi Linfen Linfen Steel is attending a hospital burns burns and other diseases. Hot water boiler is essential hospital equipment heat, hot water output can provide disinfection of medical instruments and ward heating demand. With constantly improving our environmental policy, boiler correspondingly introduced more sophisticated Use. Linfen hospital burns to respond positively to the national environmental policy, decided to introduce an environmentally friendly low nitrogen gas hot water boiler. Taking into account the special circumstances of the hospital, the boiler should also have the use of safe, clean overall characteristics. Based on the above considerations, finalize the Linfen hospital with burns boiler party cooperation fast, fast is provided by one side of a gas condensing pressure hot water boiler (CWNS2.1-95 / 70-Y.Q).

Features 10 1 atmospheric fired steam boiler textile industrys, hot water boilers controller computer, all the functions are stored on a magic smart chip, a key to power boilers, automatic timing, temperature operation, the user can set the start , shutdown time, the setup is complete, no special duty to save time, and effort. 2, the burner configuration imported brands, high degree of automation, automatic purge controller according to the instruction, the electronic auto-ignition, spontaneous combustion, air oil (gas) automatic ratio adjustment, security and stability performance, good combustion. And there are flameout protection device, ensure safe operation. 3, the inner fire tube inserted spoiler retardant, smoke slow speed, to strengthen the heat exchanger, the temperature of the flue gas discharged from a low smoke chamber, reducing heat loss and save fuel. 4, large font display temperature, easy to grasp and boiler operating conditions of the system, the water temperature can be freely set from 10 ℃ to 90 ℃, automatic boiler or heating system to provide users with life, bath with hot water. 5, the control system in accordance with the temperature control of boiler water circulation pump start and stop, boiler water circulating pump starts when the water reaches an upper limit temperature, lower than the hot water circulation pump stops when the water temperature lower limit. 6, horizontal fuel gas hot water boiler three return all wet back structure, using a large furnace, rough smoke tube design, increased furnace radiation heat absorption, the effective energy saving. Using threaded pipe and waveform furnace, greatly enhanced heat transfer effect, greatly saving fuel consumption. 7, while the machine is equipped with thermal protection (ultrahigh temperature furnace, the burner is automatically stopped and an alarm buzzer, the second over protection (the boiler shell temperature exceeds 105 deg.] C, the secondary circuit is automatically cut off), the lack of anti-dry protection of water (when water is lower than the low water level of the furnace, the boiler is stopped and an alarm beep), a boiler leakage protection (the control system detects electrical leakage, short circuit, automatically cut off the power) .8, according to the boiler pressure design , no pressure in the boiler state, there is no safety hazard .9, using advanced multi-layer insulation centrifugal glass wool, steel for packaging famous white color, heat loss, anti-rust appearance .10, gas heating boiler is widely used in homes, villas , hospitals, schools, hotels, restaurants, fitness center, bath center and other enterprises.

Free Chat

About Us

Contact Us