Manual Grate Steam Boiler

Manual Grate Steam Boiler

What is that boiler soot blowers? What impact on the operation of the boiler there? Soot Blower concept: long-term operation of boiler, heating surface fouling and coking occur, so that the deterioration of the heat transfer for the back pass, because the long-term accumulation of fuel, and then burning accident will occur which results in the boiler section after the time needed to work soot blowing heating surface, to clean the heating surface.

How flue gas condensing boiler condensate Henan excessive treatment? When Henan gas condensing boiler furnace particularly in cold start operation, the heating surface and the rear of the boiler smoke box at the rear often flue gas condensation water generated, so that the boiler stokers mistaken leaking. Henan condensed water generating smoke gas condensing boilers are mainly two reasons: 1 flue gas to condense water vapor at a temperature below the dew point; 2 Henan high gas condensing boiler thermal efficiency, low exhaust gas temperature... Henan gas condensing boiler flue gas temperature slightly higher than the dew point temperature of the flue gas can be economic security operation at rated load, but Henan gas condensing boiler in the case of low load long-running, flue gas temperature is lower than the dew point temperature of flue gas, in this case the condensed water from flowing out of the tail heating surface of the boiler, the boiler is discharged from the smoke box. A German boiler remind you: hot water boiler condensate produced during operation should be promptly eliminated from the boiler, because if excessive accumulation of condensed water will affect the normal operation of Henan gas condensing boiler can cause serious after the smoke box door and smoke box flange connections leaking. Specific measures include: 1 Henan gas condensing boiler condensate outlet is provided in the rear box to smoke condensate water can be discharged, the outlet valve is disposed generally not taken over, seal should be provided to prevent the flue gas from the tube Yi out. 2. smoke box provided to take over the outlet flue gas condensing boiler Henan discharging into the chimney smoke box, because heat is still continued cooling chimney, flue gas water vapor condenses continues in the chimney wall, in the form of small droplets flow down the chimney wall, and therefore should be set to take over the smoke box outlet, the condensed water can be discharged into the trench or any drainage system. Henan flue gas condensing boiler condensate phenomenon should cause too much concern, although the condensed water can not be avoided, but too much condensed water, bound to have a safe operation of the gas condensing boiler Henan have an impact.

(1) on the inside and outside gas boiler inspection, such as pressure welds, corroded steel inside and outside part of the phenomenon, if found should be repaired in a serious flaw, if the defect is not serious next time also to be shutdown to repair, if found when there is suspicious, but does not affect safety, records should be made for future reference.

Battle blue horn sounded, emissions of sulfur, nitrogen and oxygen compounds gradually strict national requirements. To improve the quality of the environment, but also the people a blue sky, in all industries around the environmentally friendly product revolution, Hainan Sinochem Pharmaceutical companies are no exception. By the company investigation and comparison of boiler products, in March 2017 signed a six-ton ​​steam-cleaning integrated condensing gas boiler and steam fast boiler. Tested and post feedback, the boiler equipment installation qualification, operating normally, and successfully passed the inspection by local quality inspection departments of the boiler.

Free Chat

About Us

Contact Us