8 Ton Gas High Efficiency Boiler

8 Ton Gas High Efficiency Boiler

If a single burner extinguishes, there may also be a deviation in the center of the furnace flame, and the air pressure of the extinguished burner may change. If the fuel supply is interrupted, the oil pressure or pressure indication of the extinguished burner may decrease to zero, while the fuel and gas pressure of other operation burners may rise. After the occurrence of the above situation, the 8 ton high efficiency boiler must be handled in a timely manner to ensure the safety of use.

Recently, Wuhan City, introduced in 2019 to embrace the blue sky action plan for speeding up the optimization and upgrading of industrial structure, promote the optimization of energy structure adjustment, implementation of transportation restructuring, deepen industrial pollution control and other tasks proposed solution.

Among them, in terms of optimization and upgrading of industrial structure, we will study and formulate more stringent industry access threshold, no new heavy chemical and paper industry projects within 1 km of the Yangtze River and Hanjiang River shoreline. Strict implementation of ecological protection red line, the bottom line of environmental quality, resource utilization on the line, environmental access a list of constraints.

In optimizing the energy structure, the city's ban on new coal-fired generating units, supporting the construction of new projects is prohibited owned coal-fired power stations, will not be new coal-fired boilers. Increase efforts to promote green buildings, new buildings full implementation of green building standards. In deepening the industrial pollution control, referring to Beijing and Xi'an subsidies, launched a comprehensive transformation of low nitrogen gas boiler. Before the end of 2019, the district completed at least 50% of the area within the low-nitrogen transformation tasks 10 steam tons / hour or more gas-fired boiler.

Gas oil furnace gauge acceptance and prohibit the use of instructions for conducting oil furnace oil furnace gas this kind, since both sites 8 ton high efficiency boiler products, is one of the sites keywords, therefore, requires a comprehensive knowledge and understanding. Moreover, it is also a common oil furnace type. Therefore, only familiar with this kind of boiler, we have the right to use, so a lot of benefit to themselves. 1. Gas oil furnace acceptance for this kind of a gas oil furnace oil furnace, which work in the acceptance, the main, are: First, when a gas oil furnace transported to the installation site, the manufacturer should be based on factory inventory, an inventory of its parts, whether there are missing and so on. Then, according to the boiler drawings, review of equipment, mainly to check its associated integrity. For example, the large boiler, during transportation, whether there is damage or deformation such problems. 2. Gas oil furnace gas pipeline for oil furnace installation, in which the pipeline installation, requirements mainly refer to "Heat Transfer Fluid heaters Safety Supervision" in, and should refer to product specifications, as well as the process of FIG. to carry out. For the line connection port, in addition to the flange on the connection should be used to this kind of welding. In addition, the pipeline arrangement, there should be a slope, typically from 2% to 3%. In the high line, an exhaust port shall be provided, at its low due outfall. For straight line pipe, if the length is more than 20m, then there should be a thermal expansion joint. 3. conducting oil furnace gas gauge, when the circumstances under which can not be used? In the gas oil furnace, pressure gauge is an important instrument, but if some situation, then can not continue to use its specific terms, it is as follows: Case 1: broken glass on the pressure gauge, or its dial scale is unclear, unrecognizable. Case 2: Pressure gauge seal is damaged, or it exceeds the test period. Three cases: for a limited gauge nail stop, if there is no pressure, the pointer can not limiting, the staple at the back. If the nail is not limiting, pressure gauge, in the absence of pressure, which is the distance between the pointer and the zero position, more than a predetermined allowable error range.

Different meaning of the data and the oxygen content of the exhaust gas fired 8 ton high efficiency boiler: A boiler oil-fired boiler which, it is explained below target, because through knowledge and understanding of this kind of boiler, can broaden everyone's knowledge, and at the same time, familiar with the different boiler type, so as to achieve a comprehensive understanding of the boiler, do not miss any of which. 1. fuel boiler, 0.5 tons and 0.35mw, its meaning is the same as you? An oil boiler, and 0.5 tons 0.35mw these two parameters, which specifically refers to, and is not the same, because the former is the rated evaporation of the boiler, while the latter refers to the rated power of the boiler or the rated for heat. In addition, in the unit, the two are not the same. So, obviously, on this issue, that the answer is not the same. 2. Industrial boilers, oil-fired boiler is why the general level? In addition, the oxygen content in the exhaust gas boiler fuel, how much is more appropriate? Industrial boilers, if its use is oil-fired boiler, then, it generally is a Class B boiler, that is, the pressure of the boiler is rated at 2.5MPa or less. Oil-fired boiler exhaust gas oxygen content and, in general, is controlled within the range of 3% to 5% is appropriate. If less than 3%, the problem of incomplete combustion occurs.

Free Chat

About Us

Contact Us