Coal Steam Water Tube Industrial Boiler

Coal Steam Water Tube Industrial Boiler

The main characteristics of the indicators coal steam water tube industrial boiler What? To demonstrate configuration, capacity, parameter and economical operation of the boiler, etc., generally represented by the following indicators to the basic characteristics of the boiler. A) evaporation industrial boilers evaporation is generally 0.1 ~ 65t / h. For the hot water boiler with a nominal thermal power of its capacity to indicate the size, in units of MW. (Ii) pressure and temperature for saturated steam production boiler, just indicate steam pressure. For the production of superheated steam boiler, the steam temperature of the steam must be marked at the outlet of the superheater, i.e., superheated steam temperature, the unit is deg.] C. For hot water boiler, the hot water temperature has rated outlet and rated the import of sub backwater temperature. With rated thermal power, rated water temperature and the return temperature corresponding to the rated nominal referred circulating water flow of water through the hot water boiler, the unit is t / h. Heating boiler (iii) an evaporator heating surface and the heating surface of the heat generation rate surface evaporation rate or heating rate is an indicator of the intensity of the boiler work, the greater the numerical value, the better the heat transfer, the smaller the amount of metal consumed boiler. Heating surface evaporation rate general industrial boiler is less than 40kg / (m · h); heating surface of the heating rate of hot water boiler is less than 83700kJ / (m · h) iv) the thermal efficiency of the boiler which is an index indicating economical boiler heat, general industrial combustion thermal coal boiler efficiency of around 60% to 82%. Sometimes, in order to measure the heat economy schematically steam boiler, are also commonly used coal or coal water vapor than the ratio expressed as the ratio of the amount of coal in the boiler per unit time over the period of time and the amount of steam production. Coal-water ratio of about the size and type of boiler, coal quality and operation management quality and other factors. Industrial boilers coal-water ratio is generally l: 6 ~ 1: 7.5. Description (a) Evaporation: desired amount of steam produced per hour steam boiler called evaporation, the unit is t / h steam boiler showed that the size of the rated capacity of evaporation, i.e. in boiler design parameters and ensure a certain efficiency. maximum continuous evaporation, also known as the rated output of the boiler (ii) pressure and temperature: the rated pressure steam boiler of the steam at the outlet of the steam or the hot water boiler rated working pressure rated pressure at the outlet of the hot water boiler is called, and He said maximum working pressure, in units of MPa (iii) an evaporator heating surface and the heating surface of the heat generation rate: refers to the heating surface of the pot soft drinks and other heat transfer medium and the flue gas heat exchange area of ​​the pressure receiving member, usually with smoke metal surface area of ​​the gas-side heating area is calculated, in units of square meters. the amount of steam per hour per square meter of the resulting heating surface, called boiler heating surface evaporation rate, in units of kg / (m · h) per hour hot water boiler m² heating surface of heat generated by the heat generation rate is referred to as heating surface, the unit is kJ / (m · h). (Iv) thermal efficiency: thermal efficiency of the boiler is a boiler effective utilization percentage of the heat input and heat boiler per unit time, also called boiler efficiency, [eta] is represented by the symbol.

The use of gas steam coal steam water tube industrial boiler added to give businesses what benefits? National emphasis on energy conservation increased year by year, which also contributed to the gas steam boiler flourish among industry, under the premise of environmental policies and to efficiency gains, companies are willing to choose both energy-saving, and high thermal efficiency of gas-fired boiler. Gas steam boiler in addition to providing sufficient high-temperature steam, but also can reduce fuel cost by reducing the combustion load input. The use of gas steam boiler will bring any significant benefits, let's take a look. 1, the biggest benefit is the economic use of gas steam boiler can save a lot of fuel costs for businesses, you do not need to spend lots of money to purchase a large amount of coal fuel, just use good cleanliness of natural gas will be able to output enough steam; they also do not We need the fuel storage site, only need to connect to the pipeline. 2, security is well known that natural gas is a very safe and stable, non-toxic and pollution-free, good cleanliness of fuel, liquefied petroleum gas or gas leak after not deposited on the ground, and even cause accidents will burn again. Process gas steam boiler during conveying gas selected gas is the most secure, but also easily found after leakage during use and therefore is the most secure way. 3, convenient gas steam boiler in the use, operation is very convenient, so will much favored by all walks of life. Because the use of all natural gas pipeline, a sustained run without any problems. Eliminating the need to transport coal use and clean-up or stacking cinder and other tedious work. 4. Clean the reason why gas steam boiler in the market to get a high rating, but also because it is clean and not contaminated during use, and does not produce black bottom of the pot, there is no air pollution. Thus, in use, compared to other boiler is the cleanest way.

Such as hotel Home Hotel Group is one of the three major brands, in 300 cities in the country has nearly 2,000 hotels. Home Inns has won China Golden Pillow Award for Best Chinese economy hotel chain brand award, in 2014, Home Inns brand value of $ 420 million of selected China's top 100 brands. April 4, 2016, BTG hotel groups such as the privatization of the hotel purchase transaction has been completed delivery. In mid-2016, as a Beijing hotel with our preliminary communication, the urgent need two coal steam water tube industrial boilers work of heating and hot water supply. I related technical engineers and recommend it to calculate the number and size of the boiler on the hotel room as hotel Willy sharp V6-99 two models.

Gas-fired steam coal steam water tube industrial boiler principle gas steam boiler with natural gas, liquefied petroleum gas, fuel gas such as city gas as fuel, the combustion in the furnace heat put out by heating the pot water, and which is vaporized into steam energy conversion device. Water pan (drum) is continuously released from the combustion of a gaseous fuel energy to heat the furnace, raising the temperature and generating steam under pressure, since the boiling point of water with elevated pressure is raised, the pot is sealed, the water vapor inside the expansion pressure is generated is limited thermodynamic form (strictly speaking, water vapor in the boiler water is heated to a constant-pressure steam drum regasified saturated formed) is widely used as an energy source. Boiler and boiler shell consists of two main furnace and ensure accessories, ancillary equipment instrumentation, control and protection system safe and economic operation of its continuous constituted. This boiler is a boiler drum with a water cooling wall at about the subregional arrangements drum pyrotechnic two return pipe, before the folded portion of the drum front smoke box. Between the drum and the tank in connection with the downcomer tubes and water-cooled bi, constituting the frame of the combustion chamber. There upper steam separator drum to reduce the water vapor out of the tape. Pan heating surface of a lower portion of the drum, and the water cooling pipe bi pyrotechnic tube. The basic components of a steam boiler and a steam boiler operating principle is constituted by a series of devices can be roughly divided into two main parts and auxiliary equipment. The main components of the boiler are: 1. Furnace: fuel burn-up and ensures that the boiler outlet gas temperature to a value of convection heating surface cooled safe work; 2, economizer: utilizing the heat of the flue boiler feedwater heating, to reduce the exhaust gas temperature, fuel economy and functions. 3, the drum: the respective heating surface and joined together and the boiler water wall tubes and other components decreased water circulation circuit. Soda storage drum, can adapt to changes in load, with internal steam separator means to ensure the quality of soft drinks, no DC boiler drum. 4, water wall: mainly radiation heating surface of the boiler, the absorption of radiant heat furnace heated working fluid to protect the furnace wall and the like. 5, combustion equipment: the fuel and air required for combustion of the fuel into the furnace ignition and stable good combustion; 6, air preheater: heating the fuel with air, in order to enhance ignition and combustion; flue gas waste heat absorption, reduced exhaust tobacco temperature, increase boiler efficiency. 7, the furnace walls: a housing to protect the boiler, since sealing and insulation. Heavy furnace wall of the small boiler may also function as a support member boiler. 8, the frame: a support member and the fixing boilers, Purple east 15:33:06 boiler auxiliary equipment are: 1, the wind equipment: induced draft fan and chimney via the flue gas generated in boiler operation sent to the atmosphere. 2, dust removal equipment: removing fly ash in the boiler flue gas. 3, the fuel supply equipment: fuel storage and transportation functions. 4, water supply equipment: water pump water supply through the water into the boiler by the processing device to. 5. Dust Cleaner equipment: removing ash from the boiler and carried away. 6, the blower device: by the air blower after exports the furnace air preheater and a coal grinding device heating applications. 7, the automatic control device: automatic detection, process control, automatic protection and automatic adjustment. IMPORTANT boiler maintenance and a maintenance, water maintenance method 1. The boiler must be a qualified treatment, which is to extend the life of the boiler, ensure the safe operation of the gas and steam. 2. The water temperature should be close to the furnace temperature, preferably above 20 ℃. 3. The need for low-water cutoff periodically inspect maintenance and cleaning. Water Level Controller cleaned at least once a month, rinse water table at least once a day. Rinse water table should be at the highest level; after flushing the water level should not be less than the minimum safe level, not as a net wash, can wash many times, but it must be flushed at the highest level. 4. require periodic blowdown operation, daily (per shift) at least once, after the sewage drain valve should be checked whether the influence by dirt and leaks; if it must be excluded. 5. Shutdown the steam pressure is not maintained, the boiler will produce steam space negative pressure air entrapment, and therefore should rise again to the fire burning total steam valve is opened. 6. smoke tube fouling will lead to increased exhaust gas temperature, so that boiler efficiency is lowered, so that the fuel consumption increases, it should periodically open the front door, brushing or blow smoke tube fouling.

Free Chat

About Us

Contact Us