Gas Hot Water Boiler In Serbia

Gas Hot Water Boiler In Serbia

When we use the boiler, it is unavoidable to have faults or abnormal phenomena, but in order not to affect the normal use, when the boiler appears problems should be dealt with in a timely manner, then in the face of all kinds of circumstances, how should we deal with it? Share with you some ways to handle exceptions. If only the boiler circulating pump abnormal, such as its current reduced, outlet pump pressure return to zero, which means that the pump is idling non-oil, may be caused by vaporization of oil. Therefore, first of all, Yang should take measures to identify the cause of vaporization; if the filter blockage causes the circulating pump to empty, the by-pass cleaning filter should be opened immediately; such as the new heat transfer fluid containing water or Water-decomposing gas is not excluded in the system, then the open valve should be opened immediately. If the circulating pump pressure is constant, the current increases and the flow rate decreases, the heat transfer fluid is metamorphic and the viscosity is increased, so it should be replaced or regenerated in time. If the gas containing water or decomposing is not excluded from the system due to the new heat conduction fluid, the gas should be discharged immediately by opening the valve. When the current of the circulating pump is lower than the normal value, it shows that the efficiency of the circulating pump is lower and the flow rate is decreased, which may be the fouling blockage of the heating pipeline, and the stainless steel chain should be cleaned. If the pressure difference between the front and back of the filter in the boiler increases and the pressure of the pump inlet drops, the filter may be blocked. The bypass should be opened and the filter should be turned on. Remove cleaning. In addition, the low outlet temperature of the liquid-phase heat carrier furnace and the lack of heat supply are mainly due to the problem of ash accumulation, so soot-blowing should be carried out in time. A more common problem with the boiler's grate is that it is stuck because it is broken or loose after the pin has fallen off; metal inclusions in the coal trap the grate; the grate is arched; and the tip of the slag stopper sinks to jam the grate. In view of this phenomenon, it is necessary to clean up the debris with the plate hand-down converter row, replace the broken furnace platoon and start again, if it is stuck again after the start-up, then check the causes after stopping the rotation and solve the problem in detail. At the same time, it is necessary to adjust the screws on both sides and tighten the grate, if it is still not correct. Often, you need to change the sprocket.

The reason you must know the problems of energy consumption boiler (boiler exhaust gas temperature) produce exhaust gas temperature of the boiler problem (1) shift the center position on the furnace flame, the exhaust gas temperature rises a multi-burner into the upper interlayer with the wind unreasonable . b upper stoker coal excessive. c burner tilt position shifted, resulting in the shift of the center position of the flame. d burner auxiliary throttle opening degree command deviations, lack of oxygen, pulverized coal combustion delayed. e a high-pressure fan outlet, wind speed is too large, the pulverized coal combustion furnace into the shift position. f leakage boiler, the furnace excess air factor export. g coal is too thick, ignition and slow combustion reaction. h low volatile coal, high ash, high moisture, ignition difficulties, to delay the combustion. i mill outlet temperature is low, the air entering the furnace temperature was lowered powder mixture, combustion delay. (2) When the boiler "four leak" for plugging, resulting in a superheater, reheater or economizer to reduce heat transfer area. (3) the supply air temperature is high. 4) high flue gas dew point temperature. (5) soot blowing equipment investment is not normal. (6) heating surface coking, fouling. (7) The air preheater ash fouling, heat transfer efficiency is lowered. (8) strict quality control, internal heating surface fouling. (9) low water temperature.

In recent years, the increasing popularity of Yichun City, Jiangxi Province comprehensive energy saving coal-fired boiler upgrade project, plans to eliminate 75% of the downtown 10 steam tons / hour and below the coal-fired boilers, a ban on new 20 tons of steam / hour and less fuel coal boilers; the rest of principle, then the new 10 steam tons / hour of coal-fired boilers.

Following this, Jiangxi Province Department of Finance issued a special subsidy fund boilers, Yichun downtown 2015--2016 phase-out 10 steam tons / hour coal-fired boilers companies grant. The subsidy standard is: 2 out of steam tons / hour and coal-fired boilers, subsidies to 10,000 yuan / Taiwan; out of steam 2-10 t / h coal-fired boiler, subsidies for 20,000 yuan / Taiwan.

Improve the thermal efficiency of gas steam boiler, to reduce the scale of the heating surface regardless prevention, gas steam boiler after a long run, it will produce some more or less scale. Gas steam boiler in operation, the furnace will be a series of chemical and physical reactions, in use, will form a hard and dense scale on the heating surface, which will directly result in reduced heat transfer efficiency of the boiler; and by corrosive effects of scale, will lead to reduced water wall furnace heat absorption gas steam boilers, which reduces thermal efficiency, waste input costs. The need to clean up the scale there is little that the boiler is to make long-term stable operation down. Scale thermal conductivity of only one percent of the steel, once the heating surface fouling, so that the heat transfer will be impeded, during use in order to maintain a constant output of the boiler, it is necessary to increase the temperature of the fire side. The outlet temperature of the furnace gas steam boiler is increased during the process, so that it will lose gas steam boiler is increased, so that effective heat transfer will reduce the equipment fouling in the water wall, so it is very likely It can cause water wall tube wall temperature increases lead to burst pipes water wall. Cleaning the boiler becomes particularly important. Performing the cleaning process, you can use efficient, environmentally friendly and non-corrosive cleaning agent, so that the device will be exposed to the original metallic tube, reduced to fouling. Secondly, after ignition gas steam boiler, flue gas temperature of the furnace needed to observe changes and the main steam temperature; when the main steam pressure is on the rise, if the boiler ignition, the smoke temperature rise speed or does not rise significantly Pianman, immediately check the oil on fire the gun.

Free Chat

About Us

Contact Us