Our hotel attaches great importance to environmental protection philosophy, always bear in mind the protection of environmental quality in Xiamen. Therefore, we chose to stay ahead of the fast boiler industry cooperation in clean and green boiler, electric 20 th steam boilers party fast to ensure that we provide the normal work requirements at the same time, has a very clear environmental performance. --customer feedback

The reason the gas boiler burner increased noise analysis when making use of the gas boiler and found this small fire normal, but this time turn the fire, extinguished or flashing instability. First speaking, that is because of this fire damper of the air volume setting is too large; i.e. after an oil fire because the micro-switch valve (damper outermost that group) inappropriate setting (set lower than the fire damper of the air flow larger) burner gas noise increases, mostly because the oil shut-off valve which is closed or lack of oil into the oil filter clogging; or, this is because of low temperature into the oil, the viscosity is too high or the pump into the oil temperature is too high; oil pump failure; fan motor bearing damage; there is because the fan impeller dirty equipment resulting in large noise. The above-described failure when using gas boiler, but also because the viscosity is too high oleaginous easy to be atomized (heavy oil); cyclones and because improper disc and the nozzle pitch; Note that because the fire is worn or dirty nipple; also because this preparatory tank the heating temperature is too high, causing the oil pump oil feed steam does not conform; or because the fuel inside the boiler resulting aqueous oil. When the above-described fault gas boiler used to perform this process, the test should be done gradually decreases; after heating temperature should be; adjusting the distance (between 0 ~ 10mm); clean or replace; is set to about 50 deg.] C to about; or drain oil change.

The main function is to ensure that the monitoring system burner safe and stable operation, the main components are: flame detectors, pressure monitors, temperature monitors and the like. Flame detector: monitoring conditions for forming the flame, and generates a signal reporting programmer. There are three main flame monitoring: photosensitive resistance, electric eye UV ultraviolet, ionizing electrode. Pressure Monitor: generally used for a gas burner, the main high-pressure gas, low voltage detection, and detecting elegant, if burner for 20 th steam boilers, and steam pressure monitoring. Detector Temperature: monitoring and controlling the temperature of fuel (heavy oil).

Industrial boilers can do much tonnage? Industrial boiler range is very wide use, chemical, food, power plants, textile, paper making, metallurgy and other industries need to use the boiler. People often say that industrial boiler equipment including industrial 20 th steam boilers, hot water boilers, and other industries. Pioneer fast boiler is a boiler, gas boiler electric field, it can be made into industrial boilers from 0.5 to 130 tons according to the needs of different tonnages. Fang quick existing boiler over 200 kinds of models, should your business have a need for industrial boilers, then please feel free to call.

Free Chat

About Us

Contact Us