8 Tons Wns Gas Fired Steam Boiler

8 Tons Wns Gas Fired Steam Boiler

When gas boiler outage, we should not panic, there must be the order of the operation, shut off the gas boiler. 1, the normal shutdown sequence, check the gas fired boiler fuel, gas, water shutdown valve meets the requirements; 2, off gas, coal boiler blowdown valve to prevent the surface of boiler drum cause other problems; 3, quickly closing the main steam valve prevent dehydration gas fired boiler drum; 4, close the supply valve and deaerator power switch and gas valve.

Gas 8 tons wns fired steam boiler loading, installation considerations gas steam boiler is a very wide range of special equipment, usually built in the boiler room. However, its load, the installation process, some issues must be taken, otherwise it may cause a certain degree of economic losses. 1, the process of handling and transporting gas in a steam boiler to be noted the following: the lifting capacity of the lifting device should be matched to the weight of the boiler Lifting. Can not be used for lifting has a length marked with a lifting lug can not be used should be chosen on the boiler rope, rope length to avoid inappropriate, leading to scratching furnace. In the loading, unloading and handling process must ensure that the boiler without any damage. 2, installation of boiler maintenance reserve space, make sure there is enough space for maintenance around the boiler. 3, the base gas steam boiler, the base of the boiler and precautions to be installed on the basis of 100-150mm above the floor of the boiler on the premises, subject to prior confirmation boiler manufacturing company with technical personnel, in accordance with the basis for construction drawings. Must stay out of anchor bolts embedded hole basis. Foundation must be able to withstand the weight of the boiler and the largest holding water amount. When the mounting base, must first be positioned. After the alignment adjustment in the end the length of two diagonal lines of the same base, then the entire tightening the fixing bolt. Base mounting reference line marked for reference. 4. General Precautions Be careful not to tilt too boilers and accessories and be impact. Can not be placed outside the boiler fuel. Do not dirty oil and water boilers should generally be installed in a separate boiler room, the new gas steam boiler room should not be connected to the house. A boiler can not be connected, (B) and (C) use of flammable liquid fire risk room. If the production plant is connected to the other, separated by a firewall application. 5, fire resistance rating of the boiler room of the building and fire safety requirements should be consistent with "architectural design code for fire protection" and "design of tall buildings for fire protection" requirements. Gas-fired steam boiler room on the ground should be smooth, non-flammable, no water, load-bearing foundation should meet the requirements. Gas-fired steam boiler supply voltage should be stable, to avoid burn electrical components. The voltage instability, is recommended to install regulators. To set the boiler room ventilation equipment, to maintain the boiler temperature at 50 ° or less.

Car accessories types of complex processing, such as the interior wall Peng, floor, seats, instrument panels, sound systems, many processes required in a high temperature environment, the temperature becomes optional metrics wind Visteon hot water boiler. It is reported that Dongfeng Visteon existing boiler equipment can not reach the growing production needs, the introduction of fast boiler production of two parties often piezoelectric hot water boiler (CWDR1.8-95 / 70-II) in 2017.

Gas 8 tons wns fired steam boiler how gas consumption is calculated: gas consumption gas steam boiler how to calculate: there are a lot of users do not know how to calculate the gas consumption of gas steam boiler steam boiler gas before you buy, there are a lot of phone users consulted, this this problem has plagued some users, it decided to write it again this morning article on "how gas consumption gas steam boiler computing", following on from me explain to you about the principles of operation of the gas boiler gas consumption formulas and gas boiler. 1. First, we first look at the gas steam boiler operating principle: the pressure of the fuel through the gas line is controlled by the flow valve through the ignition burner Automatic combustion air, the heat emitted by the heating surface of the boiler sufficiently absorbed (three return) flue gas (carbon dioxide and water) into the atmosphere through the chimney. 2. Gas-fired steam boiler fuel consumption cost analysis (we have a 4-ton gas-fired boiler, for example) fuel light oil and gas projects Rated evaporation 4t / h2t / h thermal efficiency of 92% to 92% fuel heating value 8500Kal boiler / Nm310300Kal / Kg fuel consumption amount 300Nm3 / h24Kg / h auxiliary mechanical and electrical consumption 11KW · H11KW · H fuel Price yuan / Nm3 yuan / Kg fuel costs per hour yuan per hour RMB auxiliary mechanical and electrical consumption costs the first year cost of fuel (million, according to 350 days / annualized) in the auxiliary equipment costs (million yuan, according to 350 days / year basis) of the total cost (million, according to 350 days / year basis) (Note: at 12 hours per day)

Free Chat

About Us

Contact Us