Thermic Fluid Boiler Oil Fired

Thermic Fluid Boiler Oil Fired

Construction of gas steam thermic fluid boiler fired steam requirements for the construction of a gas boiler requirements, gas steam boiler installation for the construction of the boiler room have certain requirements, must comply with national requirements in the construction process. Gas and steam 1, the construction of a gas steam boiler room requirements 1) boiler room must comply with the "boiler energy saving technical supervision and management regulations" and "industrial boiler room design specifications" requirement. Gas steam 2) boiler room should have sufficient light and good ventilation, have the necessary antifreeze measures. And boiler room should stay away from schools, housing and densely populated areas. 3) the position should be close to the boiler room heating equipment, in order to reduce head losses and heat loss from the hot oil piping circulating pump. 2, furnace heat carrier device is arranged in claim 1) the sump should be lower than the lowest position of the heat carrier furnace and heat system 1 m, in order to put the net organic heat boilers and systems, sump and furnace heat carrier spacing less than 5 m or separated by a partition wall. It should be fitted with a sump exhaust pipe, which exhaust pipe diameter should be large and specifications than the inflation tube. 2) position of the expansion tank should be higher than the other devices and the piping system, the system must be higher than the maximum bottom level 1.5 m. It should not be installed directly above any one boiler, organic heat carrier to prevent overflow cause a fire. 3) the sump vent pipe, expansion tank, should be connected to the outdoor safety. Can not be mounted on the vent pipe to the valve, to ensure that the tank, the expansion tank to atmosphere to ensure atmospheric pressure operation. 4) the high volume of the expansion tank should be greater than 1.3 times and all the organic heat carrier furnace heat the entire heating systems is at the operating temperature is increased due to thermal expansion of volume. 5) low volume tank furnace heat carrier to be less than 1.2 times the total amount of organic heat. 6) hot oil circulation pump should be at least four weeks for 0.5 m space, and the inspection to ensure the installation routine, the need for maintenance.

Fangkuai Company has a fully-automatic PLC intelligent control system designed and developed by itself with complete intellectual property rights. It adopts a combination of mechatronic control equipment and a programmable logic controller (PLC). Take the advanced programmable logic controller (PLC) as the "central processing unit" of the control system. The control system is operated through the touch screen, which greatly improves the degree of automatic control and operation reliability of the thermic fluid boiler fired, and the operation is simpler and more intuitive.

Gas condensing thermic fluid boiler fired Gas condensing boiler Products That condensing gas boiler, the key lies in condensing technology, is a new, energy-saving and environmental protection boiler. By condensing gas boiler flue gas condensing boiler means the exhaust gas temperature can be reduced to 50 ~ 70 ℃, full recovery of the latent heat sensible heat of flue gas and steam, the highest thermal efficiency of the boiler up to 102%. Gas condensing boiler uses condensing gas boiler products can be widely used in hotels, schools, hospitals, textile mills, cafeterias, restaurants, food plants, pharmaceutical plants, packaging plants, building materials factory, swimming pool and other enterprises place. Advantages of gas condensing boiler 1, one-piece design condensing boiler boiler efficiency compared to more ordinary, more environmentally friendly. 2, a condenser and an economizer disposed tail, achieved using a flue gas waste heat step, fully absorbed the heat in the flue gas; high heat transfer coefficient of the threaded pipe, the effect of convective heat strengthening, boiler efficiency up to 102% . 3, classic three return, all wet back structure: low resistance, high efficiency. 4, all-furnace corrugated furnace structure, strengthen the disturbance smoke while increasing the radiative heat transfer area; increase rigidity furnace, effective to attenuate the expansion stress of the furnace, and long service life; enhanced heat transfer, the combustion of fuel more fully. 5, a large volume of the combustion chamber design, fuel adaptability, and can be fully adapted to a variety of city fuel gas, natural gas, light diesel oil and heavy oil. 6, positive pressure combustion, fuel combustion, less smoke emissions, are in line with national emission standards. 7, using the first all-welded and then pre-expanding, then Expansion of advanced technology, high quality welding, testing 100% pass rate. 8, Germany Germany Weishaupt burner, Olin Finland, Italy Riyadh Road, Germany Paterson and other well-known international brands burner. 9, condensing unit, outstanding economic performance, the lowest in the province 60,000 yuan. Product Structure gas condensing boiler using condensing gas boiler wet back three return, full corrugated furnace, threaded pipe structure, large volume of the combustion chamber is provided, the combustion more fully; tail saving additional condensing means, which can effectively absorb heat generated by the fuel, improve the thermal efficiency of the boiler, reducing input costs and reduce pollutant emissions. Advantages condensing gas boiler 1, a high thermal efficiency: economizer, the boiler and condenser integrated structure, sufficiently absorb heat and smoke emission latent heat of vaporization, high thermal efficiency more than 10% than the average furnace; 2, the exhaust gas temperature is low: energy , a condenser, a three-dimensional design, efficient heat transfer, corrosion-resistant materials, the exhaust gas temperature up to 60-90 ℃; 3, energy saving, environmental protection: flue rotary combustion technology, full fuel combustion furnace with ordinary than about 10% fuel savings, harmful gas emissions to the national standards; 4, high quality silicate insulation material and double sealing structure, thermal insulation, good sealing performance.

First, the reasons gas thermic fluid boiler fired burner ignition misfire bar: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the gas boiler ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs.

Free Chat

About Us

Contact Us