3Th Heavy Oil Steam Boiler

3Th Heavy Oil Steam Boiler

When the weather gets colder and colder, people will choose different ways of heating, one of which is more convenient is the fuel-fired boiler, but many people do not understand his use, so take a look at the following. Classification: fuel-fired boiler is a kind of boiler which uses diesel oil, waste oil and so on. Its overall structure and arrangement are similar to coal-fired boilers, and the common classification is mechanical and steam materialized. Features: the bottom of the oil-fired boiler is mostly made of the heat preservation bottom tilted to the back wall, which is the bottom of the heat preservation furnace, in order to obtain good combustion characteristics. This kind of boiler, for those who do not have a natural gas pipeline, also hope The oil-fired boiler is a good choice when the cost of normal operation of the boiler is low. The fuel-fired boiler is an important symbol of the progress of the times, in order to serve the human being well and further perfect according to the needs of the people.

Our company in the choice of boiler products, attaches great importance to the quality of emissions and 3th steam boilers, boiler low emissions of pollutants party provides fast, good steam quality is superior boiler products. --customer feedback

The main factors affecting small type gas 3th steam boiler steam boiler thermal stability of gas ignition is not difficult to establish a stable small fire signal, the root cause is a small fire detectors can not detect normal to the fire. Gas-fired steam boiler burner underlying mode, two-pass configuration, the fuel combustion, the boiler operation is stable and take up less space, while the spoiler is inserted smoke tube, smoke slow speed, increase heat transfer, a high thermal efficiency, reducing user fees biomass boilers categories: biomass boilers horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass steam boiler, biomass hot water boiler, biomass oil furnace. Function gas boiler the ignition system that ignites the mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas boiler manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. Small fire detectors use the ionization fire detection, and requires effective contact area of ​​the flame, the flame stability and proper size, the gas pressure must be controlled within a very strict range. If the ignition gas pressure is too high, too long a small fire flame is moved beyond the detection range of the small fire detection probe, the system will not be mistaken for a small fire; if the gas pressure is too small, the gas will be firing too small and the boiler the blast very, very easy to blow out the flame, the ignition is not possible. Also, fire gases found a small pressure regulator valve regulating performance is not good, fine adjustment can not be achieved. Stability is also related to a small fire and the ratio of the size of the boiler furnace pressure boiler feed valve. The damper is too large or too small can affect the stability of the flame is ignited and the flame, furnace pressure will lead to extinguish the flame. In order to ensure the accuracy of fire detection, fire detection, we can adjust the small depth of insertion of the probe, the position of the fire detection probe in the correct position, in order to more effectively detect small fires flame.

Dry: six gas-fired boiler safety procedures (hot water + steam) stage, the purchase of gas-fired boiler more and more users, in many industries, such as oil exploration, hospital disinfection, chemical production, wine feed, and so on. But many users initial contact with a gas boiler told us how to get started quickly boiler operation is not clear. First, all personnel must be familiar with the operation of the boiler boiler performance and safety knowledge, certificates; this non-job employees Never operate. Duty personnel should strictly follow the regulations, do a good job operating records and shift recording, the security situation should shift equipment and run tests, carried out. When the shift to check the boiler is intact. Second, purchasing, installing, or before the initial operation of the boiler, the boiler and safety accessories must conduct a comprehensive inspection, inspection and determined within the validity period to start. Third, Kai furnace ready to check the gas pressure is within the normal range of values, not too high or too low; check whether normal pump Sheung Shui, if unusual you need to open the purge valve until the Sheung Shui so far. Open the door of each section Water Supply System (including Sheung Shui before and after the festival gates pumps and boilers); check the water level, the water level should be in the normal position, the water level gauge, a water color need to plug in the open position, to prevent false water level, if missing water can be manually Sheung; check valves on the pressure pipe, must be opened, the wind deflector must all flue opening; each knob inspection control cabinet are in their normal position; 3th steam boiler check valve is in the normally closed state, heat water boiler circulating pump outlet valve should be turned off; check water softening equipment is operating correctly, soft indicators of compliance with national standards. Fourth, Kai furnace run time 1, steam boilers Open the power to start the burner; check manholes, hand holes around the flange and valve leaks will be tightened, if there is still leakage after tightening occurs, you need to immediately stop maintenance furnace; l when the air pressure 0.05 ~ 0.1MPa, replenishment, sewage, water supply systems and sewage screening test device while flushing water table; when the pressure was raised to 0.1 ~ 0.15MPa, rinsed trap gauge; pressure was raised to 0.3 MPa, the "fire load / small fire" knob to "fire" to strengthen the combustion; 2/3 when the air pressure was raised to the operating pressure, start warming air supply tube, slowly open the main steam valve, to avoid water hammer; out when the drain valve when steam is completely close it; after all drain valve closed, slowly open the main valve to open, and then half a turn; "burner control" knob to "Auto"; level adjustment: adjusting the water level (according to the load manually when to start and stop the pump), low load level should be slightly higher than the normal level, high load level should be slightly lower than the normal level; steam pressure adjustment: adjusting the combustion load in accordance with (manual adjustment fire / small fire) determines combustion conditions The flame color, smoke color determination condition atomisation air quantity and exhaust gas temperature observed concentration chimney, the best change in the combustion temperature to be adjusted according to the combustion. 2, start the circulation pump hot water boiler; startup burner; 15 minutes after start, "" fire load / small fire "spin-bit color button to" fire ";." Burner control "knob to" Auto "five, normal stop 1 furnace, hot water boilers' fire load / small fire "knob to" small fire "; off the burner; close the fuel supply valve; closing dampers; boiler after the temperature dropped to 50 ℃, the pump outlet valve closing cycle ; .2 circulation pump is stopped, the position of the steam boiler "fire load / small fire"; Close combustor; steam pressure drop when the sewage to 0.05-0.1MPA; closing the main steam valve; manual replenishment to the higher level; Close valve; Close supply valve combustion; closed dampers; six off the main power, an emergency shutdown, the steam boiler main steam valve closed; off the main power; 2, boiler water boiler inlet and outlet valve closed; opening the emergency valve and the emergency discharge replenishment valve; off the main power switch; notification superiors.

Free Chat

About Us

Contact Us