Best Sales Oil Steam Boiler

Best Sales Oil Steam Boiler

Gas-fired best sales steam boiler abnormal situation, how should we deal with it? When we use gas steam boiler, failure or abnormal phenomena it is inevitable, but in order not to affect the normal use, in the event of a problem gas steam boiler to be timely processing solutions, then the face of all kinds of circumstances, we should how to handle it? Share some of the ways we deal with unusual circumstances. If only gas steam boiler circulating pump abnormalities, such as its current decreases, the pump outlet pressure back to zero, which indicates no oil pump is idle, it may be caused by oil vaporization. Yang identify the reasons therefore first vaporized measures; such as clogging of the filter circulating pump bypass opening evacuated immediately clean the filter; heat transfer fluid as a result of added aqueous or decomposed gases are not excluded in the system, should immediately open the vent an exhaust valve. Circulation pump pressure constant, the current increases and the flow drops, deterioration of the thermally conductive fluid, the viscosity increased, should be replaced or regenerated. New heat transfer fluid as a result of decomposition of aqueous or excluded gases in the system, should immediately open the vent valve of the exhaust gas. When the current is lower than normal circulation pump, the circulation pump efficiency is decreased, the flow rate decline may be heating pipes plug fouling, stainless steel chain should be cleaned. If the gas steam boiler before and after the filter increased in pressure, the pump inlet pressure drops, the filter may be stuck, the opening of the bypass, disassemble and clean the filter. In addition to its low furnace outlet temperature liquid phase heat carrier, mainly for lack of heat fouling problems, it is timely soot blowing. Gas steam boiler grate more common problem is stuck, there are reasons including breaking grate or the grate off loose pins; coal grate has stuck to metallic inclusions; arched grate; slag is sinking the tip of the grate stuck. In response to this phenomenon, the required reverse hand grate plate debris removal, replacement breaking grate after the start, then jammed as startup, stop the rotation of the reasons detailed inspection to resolve. But also to re-adjust the adjustment screw on both sides of the grate tension, if still does not work, we need to replace the sprocket.

After the project identification, party fast technical staff soon made contact with our company, to our installation, commissioning, to ensure the look normal, stable use during boiler operation. Thanks fast boiler professional technical support and good service, I provide a lot of help for the textile dyeing and finishing production company. --customer feedback

Combustion gas treatment and a malfunction due to gas boiler burner ignition misfire bar: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs. Gas Burner fails, the action bar ignition misfire following five: Clear, renewal, adjust the distance, change and switching transformer. Second, the gas boiler the ignition spark rod misfiring but the reasons: 1, the disk space ventilation carbon cyclone is blocked, poor ventilation. 2, dirty oil nozzle clogging or wear. 3, the throttle angle is set too small. 4, the firing bar from the leading edge from the oil nozzle tip inappropriate (too protruding or retracted) 5, the first solenoid valve is an oil debris blocking gun (gun small kerosene). 6, oily or too viscous to flow easily clogged or the oil filtration system the valve is not opened, so that insufficient suction pump, oil pressure. 7, the filter pump itself blocked. 8, the oil more water (boiling abnormal noise within the heater). Gas boiler ignition spark rod action but misfiring are: clear; the first washing, such as not renewed; turndown test; adjusting the distance (in 3 ~ 4mm as well); Remove cleaning (cleaning the parts diesel) ; check the pipeline and oil filters, insulation equipment; peripheral screw pump removed, carefully remove the cover inside out net oil, diesel oil immersion; renewal of the test oil. Third, when the gas boiler and turn the fire a small fire normal, off, or flashing the causes of instability: 1, air volume damper setting fire too. 2, oil fires micro switch valve (damper outermost that group) inappropriate setting (set throttle air flow rate is greater than the fire). 3, oleaginous easy to spray viscosity is too high (heavy). 4, and the nozzle plate spacing cyclone inappropriate. 5, fire nozzle worn or dirty. 6, the preliminary fuel tank temperature is too high, so that the steam not smooth oil pump oil feed. 7, gas hot water boiler fuel oil water. When a small fire gas boiler normal and turn the fire extinguished or flashing instability action: Test gradually reduced; heating temperature; adjusting the distance (between 0 ~ 10mm); clean or replace; i.e., set to about 50 deg.] C may be; or drain oil change. Fourth, the noise increases gas boiler burner reasons: 1, cut-off valve is closed or the passage into the fuel shortage, an oil filter blockage. 2, the oil inlet temperature is low, the oil viscosity is too high or the temperature is too high the pump inlet. 3, oil pump failure. 4, fan motor bearing damage. 5, dirty fan impeller. Burner gas treatment increased noise: ① the check valve in the oil line is open, if the oil filter is working properly, the filter cleaning pump itself. ② heating oil or reduce the oil temperature. ③ Replace the oil pump. ④ replace motor or bearings. ⑤ cleaning fan wheel.

The development trend of environmentally friendly eco-friendly hot water boiler hot water boiler ushered in new opportunities. Late last year the State Council issued energy-saving environmental protection industry. Environmental protection boiler is also more and more attention in the boiler industry, in which major favorable policies, the mountain pot boiler seize the opportunity to develop environment-friendly hot water boiler, and its development trend did some summary for everyone to share now study and discussion, together with the conduct. The development trend of environmentally friendly hot water boiler specifically in the following areas: high-efficiency boilers; using simple auxiliary sets; simple structure; the whole intelligent automatic control and is equipped with multiple-level protection system. Environmentally friendly hot water boiler is on the whole have the following requirements: size and weight were reduced, which reduces the footprint of hot water boilers, boiler room would not need so much construction, weight reduction will saving materials, use of new materials to replace the old materials to improve the life of the hot water boiler, also during transport in many aspects, reduce unnecessary trouble. Improve boiler efficiency reduces fuel combustion, thus reducing the consumption of natural emissions of flue gas and water; and increase the degree of automation assembly, boiler maintenance so it will be more convenient, where you do not have the repairs carried out accessories and replacement is simple and convenient, automatic application of the procedures boiler with higher intelligence. Especially in recent years, the use of some new combustion technology and enhanced technology, the volume of oil and gas hot water boiler heat transfer is greatly reduced than before. Our industry has made great strides in development, people's general requirements of hot water boiler will be more stringent. This requirement is mainly to solve the contradiction between economic, security, usability. Mountains pot hot water boiler with a mature technical team, developed a hot water boiler in line with customer requirements for environmental protection, we have made many achievements in the hot water boiler market. Our mountain pot boiler satisfied with the existing results, as always, based on the market, focus on the future, to develop more high-quality environment-friendly hot water boiler, make a contribution to environmental protection. Gas boiler steam cleaning and maintenance measures combustion gas best sales steam boiler is first opened the door, the rear housing panel removed, screwing the rear open boiler cleaning opening. Clean fuel gas piping with a wire brush. With a soft brush to clean the combustion chamber. Gas steam boiler to remove residue in the boiler, the cleaning opening is screwed on the screw, closing the burner door seal check is complete. If the boiler is installed in areas where temperatures below 0 ℃ must take the following precautions: If outside the boiler room, the room temperature drops below 15 ℃ or 18 ℃, the whole day operation of the boiler. If a long time no one in the room should be emptied of water in the boiler. You know cathodic protection of each member constituting the boiler (such as iron, copper, aluminum, etc.) of different materials. In order to prevent galvanic corrosion, cathodic protection measures must be taken. Sewage treatment boiler. The bottom of the gas-fired boiler flue gas emissions to prevent condensation. Since the flue gas is flue gas condensation (diesel or natural gas) and the flue gas temperature in the aqueous too low, water generated. A portion of the moisture is discharged from the chimney, the chimney wall is absorbed, the rest is deposited on the bottom of the chimney. Water produced by the following factors influence: flue gas temperature (efficiency 91%, the flue gas must be at a temperature of 170 ℃) where the total surface area heat chimney, chimney and chimney material. Maintenance of the burner. Gas boiler and burner maintenance, the best maintenance after steam supply. Because the products of combustion will corrode the boiler, clean up carbon deposits, therefore, not allow the products of combustion burner door opened first time in memory, leaving the boiler is too long, remove the rear housing panel, tighten the screws to open the rear side of the boiler clean mouth. Clean fuel gas piping with a wire brush. With a soft brush to clean the combustion chamber. Gas steam boiler to remove residue in the boiler, the cleaning opening is screwed on the screw, closing the burner door seal check is complete. If the boiler is installed in areas where temperatures below 0 ℃ must take the following precautions: If outside the boiler room, the room temperature drops below 15 ℃ or 18 ℃, the whole day operation of the boiler. If a long time no one in the room should be emptied of water in the boiler. You know cathodic protection of each member constituting the boiler (such as iron, copper, aluminum, etc.) of different materials. In order to prevent galvanic corrosion, cathodic protection measures must be taken. Sewage treatment boiler. The bottom of the gas-fired boiler flue gas emissions to prevent condensation. Since the flue gas is flue gas condensation (diesel or natural gas) and the flue gas temperature in the aqueous too low, water generated. A portion of the moisture is discharged from the chimney, the chimney wall is absorbed, the rest is deposited on the bottom of the chimney. Water produced by the following factors influence: flue gas temperature (efficiency 91%, the flue gas must be at a temperature of 170 ℃) where the total surface area heat chimney, chimney and chimney material. Maintenance of the burner. Gas boiler and burner maintenance, the best maintenance after steam supply. Because the products of combustion will corrode the boiler, clean up carbon deposits, therefore, not allow the products of combustion in the boiler stay too long memory

Free Chat

About Us

Contact Us