Wns Series Fire Tube Gas Boiler

Wns Series Fire Tube Gas Boiler

Calculated gas steam wns series fire tube boiler plant to explain your boiler heating area: Gas-fired steam boiler plant to you to explain the calculation method of gas steam boiler heating area of ​​the boiler, which is sure to install emissions-line monitoring devices, and, should environmental protection department of the monitoring center networking, so the job. And this kind of boiler heating area, specifically, then, is to be determined according to the location of the boiler, its usage and requirements. Generally speaking, if it is 1 ton, then, it is about 7000 square meters of heating area. 4 tons of gas steam boiler, which uses induced draft fan, then, that in the selection and configuration, generally speaking, if a different motor, then, there is a different choice, but specifically, then, is there are two First, Y5-47-6C, power is 15KW / 18.5kw, grade 2 is a motor; Second Y6-41-7.1C, power is 15kw / 18.5kw, the motor is four. 10 tons of gas steam boiler, between it and the workshop is to have a safe distance, and can not be a piece design, it must be independent. Therefore, it is generally to be more than 5 meters, so the job, however, can also be separated coal field.

Around the city to promote the coal to gas project, the major institutions of the heating system put forward higher requirements. Central Conservatory of Music is available to students and teachers clean, safe, comfortable, energy-efficient heating environment, protect the health of teachers and students, to transform the traditional wns series fire tube boiler treatment. Praise fast boiler Willie sharp series obtained in the transformation of low nitrogen boiler major institutions in Beijing, the Central Conservatory of Music in late 2017 with the signing of fast boiler boiler purchase contract, ordered six Willy sharp series V6-99, to for the entire school's heating facilities.

Method for safe operation of steam wns series fire tube boilers steam boiler before use, must be checked for damage of the insulating layer, to check the burner is operating correctly, and to check the position of the opening degree of the valve to ensure it is correct. Must be checked for automatic control instruments and equipment safety equipment accessories, equipment, in order to comply with the requirements. Check item prior to ignition of the steam boiler: open valve before oil circulation pump, oil heating valve is opened, adjusted reasonably high level of the tank, the gas pressure is determined before the natural gas burner ignition must be within the range, the power good . Refers to the operation of the steam boiler is refluxed pressure activated device circulating pump, the circulating pump outlet, inlet, outlet, and the system, it is in the normal range. Circulation pump run for 30 minutes. After the stability of the system, the next step. Open the gas tube steam boiler manual valve, button start-up burner, natural gas burner into the furnace, and then the ignition, the flame remains stable, i.e. is in a safe operating condition. In the firing process steam boiler, if you accidentally quenching phenomenon occurs, the device will automatically interlock burner saver appear. It must be promptly cut off the natural gas pipeline to start the furnace purification. Replacement of the residual gas in the furnace and closed. The system load requirements, temperature requirements and thermal oil outlet, the burner can automatically adjust the size of the fire source.

Method of reducing the exhaust gas temperature of the wns series fire tube boiler which: standard boiler exhaust gas temperature: between the boiler flue gas temperature of 200-230 deg.] C in accordance with conventional design national standard thermodynamic calculation boiler design requirements. Conventional exhaust gas temperature selected reasons, coal fired boiler combustion process will produce a certain amount of SO2, and SO2 below 170 ℃ will bind and generating flue gas H2O H2SO4 sulfuric acid, H2SO4 sulfuric acid and will form boiler heating surface of tail corrosion, thereby reducing the life of the boiler, conventional coal-fired boiler exhaust gas temperature is higher than 200 ℃. Temperature is high energy loss and more, is not conducive to energy saving. Cooling measures taken to ①, the economizer application: increasing the boiler economizer (economizer) of heat transfer area, larger than the conventional take about 1-2 times the flow cross sectional area economizer structure, effectively reduce smoke flow rate, to strengthen the heat transfer efficiency, reduce exhaust gas temperature; ②, air preheater applications: pipes connected to the air preheater economizer disposed, the apparatus can effectively increase the temperature of the combustion air, improving the ignition of the fuel condition. Very beneficial to the boiler combustion conditions. ③, adjust bidirectionality combustion system, a boiler originally designed for fuel specifications have some flexibility, different media in effect outside the combustion process are different, adjusting the embodiment, with the economizer and the air preheater using, the temperature of the boiler exhaust emission control at a suitable temperature, that make full use of heat energy, but also to ensure the integrity of the structure and function of the relative equipment, environmental protection, energy saving, security and development is the social responsibility of all of us for a rational design of industrial structure boiler, thermal efficiency is relatively high, its emissions would be relatively low temperatures, so we must be careful when choosing a boiler boiler property report form.

Free Chat

About Us

Contact Us