Automatic Oil Steam Boiler

Automatic Oil Steam Boiler

Why boiler furnace exhaust gas temperature increases heat losses the heat loss is largest in a boiler, furnace 6% is generally fed to the heat, the exhaust gas temperature increasing every 12 ~ 15 ℃, heat losses to an increase of 0.5%. Therefore, the exhaust gas temperature is one of the most important indicators boiler operation. Here are a few reasons may cause the furnace exhaust gas temperature rise: (1) heating surface slagging, fouling. Whether waterwall slagging furnace fouling, or superheater, convection bank, and economizer preheater fouling are due to increased resistance measured smoke, heat deterioration of the cooling effect deteriorates the flue gas, resulting in increased exhaust gas temperature. (2) the excess air ratio is too large. Under normal circumstances, the furnace outlet increases as the excess air ratio of the exhaust gas temperature rises. After the excess air ratio increases, while the amount of smoke increases, the speed increase of smoke, heat strengthening of exiled, but less than the degree of increase in heat transfer gas volume increases more. It will be appreciated as the tobacco rate increased, the time to heat to the flue gas working fluid left the heating surface. (3) leakage factor is too large. Tail shaft furnace and boiler flue negative pressure leakage is inevitable, and provides a heating surface allowed leakage coefficient. When the coefficient of air leakage increases, the influence of the exhaust gas temperature and overfire air coefficient increases similarly. And the closer the leakage furnace, exhaust gas temperature raising effect on the greater. (4) water temperature. When the turbine load is low or high pressure splitting when the heater temperature of the boiler feedwater will decrease. Generally, when the water temperature rises, if the amount of fuel is maintained constant, the temperature difference decreases economizer, economizer heat absorption decreases the exhaust gas temperature rises. (5) the fuel moisture. The fuel in the flue gas to increase the amount of water increases, and therefore the exhaust gas temperature rises. (6) boiler load. Although the boiler load increases, the amount of smoke, the amount of steam to the water, the air amount increases in proportion, but since the furnace exit gas temperature is increased, so that the exhaust gas temperature rises. After the load is increased to increase the furnace outlet temperature, followed by convection heating surface temperature difference increases, an increase in heat absorption, the more so the convection heating surface, the smaller the impact load change of a boiler exhaust gas temperature. (7) The fuel species. When burning low calorific value gas, since the furnace temperature is lowered to reduce the radiation heat transfer in the furnace, the low calorific value gas in a non-combustible components, mainly N2, CO2, H2O more, the amount of flue gas increases, the exhaust gas temperature rise high. Pulverized after burning oil, although oil-fired furnace outlet when the excess air ratio than the coal is low, but the little ash fuel oil, and no larger soot particles, larger ash particles in the flue gas absent the cleaning action of surface heating, convection heating surface more polluting. So bad combustion, often black smoke boiler flue gas temperature. When the tail has means ash ball, since the tail cleaner, the exhaust gas temperature is slightly lower than the burning coal. (8) milling system operation. Bunker has a reservoir of closed milling system is concerned, when the pulverizing system is running, because a portion of the water in the fuel into the furnace, the furnace temperature is reduced and the amount of smoke increases, the leakage into the pulverizing system is running as the primary cold air air into the furnace, to reduce the amount of air flowing through the air preheater to the exhaust gas temperature rises. Conversely, when the exhaust gas temperature is reduced pulverizing system outage.

February 20, 2019, the Beijing Municipal Government issued the "Beijing's pollution prevention campaign of 2019 Action Plan" (hereinafter referred to as the "Action Plan"). "Action Plan" clearly 2019 development goals: the first is the city PM2.5年均浓度, three-year moving average concentration strive to continue to decline.

Since 2018 autumn and winter, fog and haze in control efforts continue to increase. Beijing, Tianjin Fenwei Plain, the Yangtze River Delta region of the focus of supervision and maintain a high pressure situation, provinces and cities have also introduced Blue Sky Battle plan, air pollution control sector welcome the opportunity. And because the 2018 autumn and winter abolition of green "one size fits all", so that pollution from the administrative means to switch to environmentally friendly means to speed up environmental protection business orders release.

"Winning Blue Sky Battle three-year action plan" called for increased efforts to eliminate small coal-fired boilers, the county level and above urban area basically eliminated 10 tons of steam per hour and coal-fired boilers, in principle, to the new 35 per hour tons of steam coal-fired boilers. We believe that, under constant fog and haze, the small boiler phase-out process will accelerate. Research believes that by 2021 the transformation of coal-fired central heating investment 88.6 billion yuan, annual operating income of 240 billion yuan, the central heating market will also speed up the release with the environmental supervision.

Professionals expect non-electric air control about 192.2 billion market space, ultra-low emission thermal power market reform space of about 65.7 billion yuan, the whole vast air pollution control requirements.

In addition, the high diesel vehicle emissions, is also one of the main source of haze pollution. Considering the number of ministries had jointly issued by the Ministry of Ecology and environment "diesel truck pollution control tough fight Action Plan" diesel vehicles, boats become the focus of the next step of action to win the Battle of the blue sky.

Dry: six gas-fired boiler safety procedures (hot water + steam) stage, the purchase of gas-fired boiler more and more users, in many industries, such as oil exploration, hospital disinfection, chemical production, wine feed, and so on. But many users initial contact with a gas boiler told us how to get started quickly boiler operation is not clear. First, all personnel must be familiar with the operation of the boiler boiler performance and safety knowledge, certificates; this non-job employees Never operate. Duty personnel should strictly follow the regulations, do a good job operating records and shift recording, the security situation should shift equipment and run tests, carried out. When the shift to check the boiler is intact. Second, purchasing, installing, or before the initial operation of the boiler, the boiler and safety accessories must conduct a comprehensive inspection, inspection and determined within the validity period to start. Third, Kai furnace ready to check the gas pressure is within the normal range of values, not too high or too low; check whether normal pump Sheung Shui, if unusual you need to open the purge valve until the Sheung Shui so far. Open the door of each section Water Supply System (including Sheung Shui before and after the festival gates pumps and boilers); check the water level, the water level should be in the normal position, the water level gauge, a water color need to plug in the open position, to prevent false water level, if missing water can be manually Sheung; check valves on the pressure pipe, must be opened, the wind deflector must all flue opening; each knob inspection control cabinet are in their normal position; automatic steam boiler check valve is in the normally closed state, heat water boiler circulating pump outlet valve should be turned off; check water softening equipment is operating correctly, soft indicators of compliance with national standards. Fourth, Kai furnace run time 1, steam boilers Open the power to start the burner; check manholes, hand holes around the flange and valve leaks will be tightened, if there is still leakage after tightening occurs, you need to immediately stop maintenance furnace; l when the air pressure 0.05 ~ 0.1MPa, replenishment, sewage, water supply systems and sewage screening test device while flushing water table; when the pressure was raised to 0.1 ~ 0.15MPa, rinsed trap gauge; pressure was raised to 0.3 MPa, the "fire load / small fire" knob to "fire" to strengthen the combustion; 2/3 when the air pressure was raised to the operating pressure, start warming air supply tube, slowly open the main steam valve, to avoid water hammer; out when the drain valve when steam is completely close it; after all drain valve closed, slowly open the main valve to open, and then half a turn; "burner control" knob to "Auto"; level adjustment: adjusting the water level (according to the load manually when to start and stop the pump), low load level should be slightly higher than the normal level, high load level should be slightly lower than the normal level; steam pressure adjustment: adjusting the combustion load in accordance with (manual adjustment fire / small fire) determines combustion conditions The flame color, smoke color determination condition atomisation air quantity and exhaust gas temperature observed concentration chimney, the best change in the combustion temperature to be adjusted according to the combustion. 2, start the circulation pump hot water boiler; startup burner; 15 minutes after start, "" fire load / small fire "spin-bit color button to" fire ";." Burner control "knob to" Auto "five, normal stop 1 furnace, hot water boilers' fire load / small fire "knob to" small fire "; off the burner; close the fuel supply valve; closing dampers; boiler after the temperature dropped to 50 ℃, the pump outlet valve closing cycle ; .2 circulation pump is stopped, the position of the steam boiler "fire load / small fire"; Close combustor; steam pressure drop when the sewage to 0.05-0.1MPA; closing the main steam valve; manual replenishment to the higher level; Close valve; Close supply valve combustion; closed dampers; six off the main power, an emergency shutdown, the steam boiler main steam valve closed; off the main power; 2, boiler water boiler inlet and outlet valve closed; opening the emergency valve and the emergency discharge replenishment valve; off the main power switch; notification superiors.

Steam boiler fuel gas composition changes so the General Assembly cause flameout: fuel gas automatic steam boiler pressure off the fire caused by a sudden rise, the solenoid valve malfunction the gas supply interruption, the gas composition has changed so much moisture content is too high and so on. Blower, fan failure, the load is too low furnace pressure is too large excessive leakage and other excessive wind, so that the furnace temperature is too low can also cause steam boiler fuel flame. Causes fuel steam boiler flameout are: oil pump failure, the oil surface is exposed inhalation tube, clogging of the oil filter or oil supply pipe, a solenoid valve malfunction or misoperation caused by oil running intermittently. During transport the fuel with steam by heating water; inappropriate position inhalation tube with the pumping of water; improper contaminated oil floating on the water; poor dewatering tank drain plug such that the fuel with water.