Gas Steam Boiler In Senegal

Gas Steam Boiler In Senegal

As one of Beijing's air pollution emission standards of the most demanding urban, environmental control is very strict. Beijing primary school campus Emerald City as one of the cradles of socialist culture successor, in terms of the quality of students' learning environment is put emphasis on one hundred percent. October 2017, Beijing primary school campus Emerald City with my company, signed a two Thalia T6 series vacuum hot water boiler for winter heating use.

How how electric steam boiler in senegal maintenance electric steam boiler maintenance 1, boiler maintenance, must be cut off and must relief. 2, the burner every two months to be removed from the boiler, carefully remove foreign bodies such as dust and soot. Photocell light-receiving surface wipe once a month, fuel filter should always be kept clean and filtering capabilities; carefully clean the filter in the pump, do not break the seal. Oil-burner not idle, so as not to damage the pump. 3, the water level gauge should always be kept clean, rinse the purge valve is opened, the water level in order to ensure a clear day. 4, pulling the safety valve once a day, to prevent rusting failure. 5, electric steam boilers stop running long time, turn off the power, and do maintenance work: (1), dry maintenance, shutdown after the release came out water, dirt clean the furnace, with a slow fire the burner drying pot (burning time not too long, to avoid damage to the boiler), then all of the drained gas boiler, all pipe valve closed, checked every three months. (2), wet maintenance for a period not exceeding one month shutdown of the boiler, furnace shutdown after water release, discharge and clean fill with water, cut off the power, close the valve.

About the advantages of gas-steam oven gas is mainly reflected in what way in recent years, with the continuous development of the boiler industry, a variety of devices including gas, including gas-steam oven has been further developed and applied. We know that the production of each device can be widely used. It has its own advantages, the main advantage of what gas furnace gas and steam are we talking about today? According to reports, the gas can understand that gas-steam oven does not require the accumulation of ash, thus eliminating area. When the gas for a fuel delivery gas steam oven, other auxiliary machines less, low-power, continuous operation time is short, and therefore at a high level, saving electricity. Production of heat transfer oil boiler. Others because the gas furnace gas and steam will now run out of dust and pollution, natural gas is used as a clean energy source. In the Gas Gas steam oven operation, no pollution, and it is easy to achieve. Nightly environmental needs. Daily use of gas gas steam oven needs maintenance. When not in use the boiler, should carry out maintenance and maintenance. This will not only extend life, but also can reduce the use of various problems arising in the process. First of all, when not in use boiler, heat transfer oil to be discharged of all internal, because if there is oil, the quality will change. If a leak occurs, it will affect the surrounding environment, and needs to be cleaned after release. Clean the inside of the boiler to maintain and keep other impurities. Secondly, regularly check the various components of the gas oil furnace to see if there are loose. After maintenance, the boiler can be stored, can be used directly in the next use, not other problems. Xiao Bian remind you, after using a gas furnace gas and steam for some time, the loss will occur. If the loss is too large, it will affect their use, particularly in certain connections and transmission loss larger. Add lubricant to reduce the loss of these components and more stable performance of the boiler.

Teach you how to properly operate a steam boiler in senegal: steam boiler before use to conduct the inspection of the damaged insulation, burner check to see whether the normal operation, also check to ensure that the open position of the valve is correct, check the device controlled device instrumentation and safety equipment accessories, equipment must meet the requirements. Steam boiler furnace entry point confirmation are: Open the valve before and after the oil circulation pump, oil heating flow valve opens, the liquid level in the sump reasonable mediate high position, confirmed that the gas pressure before ignition of the gas burner to the range, the power supply is normal .

Free Chat

About Us

Contact Us