City Gas Fired Boiler In Belgium

City Gas Fired Boiler In Belgium

Gas city fired boiler in belgium safe handling as the country increasingly stringent emission standards for air pollution, the country has already started work boilers from coal to gas, out of heavily polluting coal-fired boilers, gas boilers using clean fuels. In this regard, Kono Tips boiler, gas boiler process, the need to pay attention to some safety issues: 1. burner to keep the working environment clean and dry, burner cleaning and maintenance once per shift to the control circuit must not get wet, affected by high temperature. 2. Check the electrical installations, mainly: whether the damaged wire, jacket damage, without loosening the screws, the contact is good, the motor is running any abnormal sound. 3. During normal operation, the burner portion close to thermodynamic device (such as a flange connection part) will be very hot, to avoid burns. Do not place near flammable materials, so as not to cause a fire. 4. combustor during startup, if the burner is locked repeated alarm reasons should be identified, and then identify failures and excluded press the reset button (pressing the reset button must not exceed 10 seconds), continue to start. 5. After the total gas pipeline experienced a temporary power failure solenoid valve (steel tile shed) to stop gas supply will automatically shut down until the first call burner electric alarm device to send, then a small hammer solenoid valve with total on hand to pull, you must first send electricity to manually open solenoid valve, solenoid valve will be closed and vice versa total. 6. fireman not mess-tune the burner, abnormal promptly notify management personnel, approved by management and then make adjustments. 7. In the long-term shutdown state, to do maintenance work on the boiler equipment, for each transmission parts to clean, lubricate.

Burner fuel gas selected selection principles which fuel gas city fired boiler in belgium burners should be based on structural features and performance requirements of the boiler body, in conjunction with user conditions, making correct comparison, several general principles according to the following options: 1) according to user selection of used fuel type, liquid fuel kerosene, diesel oil, heavy oil, residual oil and waste oil, fuel gas city gas, natural gas, liquefied petroleum gas and biogas, fuel should have the necessary analysis of data used: ① kerosene, diesel should have heat and density. ② heavy oil, residual oil and the viscosity should, heat, moisture, flash point, mechanical impurities, ash, freezing point, density and the oil temperature. ③ should calorific gas, gas pressure and density. 2) to select the type burner nozzle atomization method or the gas burner and the furnace structure according to the performance of the boiler. 3) the burner output should match the rated output of the boiler, choose a good shape of the flame, such as length and diameter so as to adapt the furnace structure. The required combustion air is supplied from the root flare fuel gas and air or oil mist uniformly mixed rapidly, to ensure complete combustion. The rated output of the boiler and boiler efficiency is determined, the fuel consumption is calculated, and then selected according to power a single burner arranged to determine the number of burners. Increase the number of burners, in favor of the atomization quality assurance wind oil mix, but too many, and not easy to operation and maintenance, will give burner arrangement difficult. 4) adjusting the burner to a large extent, be able to adapt to changes in boiler load, to ensure complete stable combustion under different conditions. 5) fuel atomization less energy consumption, adjusting the wind resistance of the device to be small. 6) Effects of noise and smoke emission must comply with environmental standards, mainly emissions S02, CO and NOx must be lower than the predetermined country, should use low NOx burners and low noise. There are integral and split two 7) a burner assembly embodiment. I.e. monolithic burner body, the burner and a combustion air blower system (including an oil pump, a solenoid valve, a servo motor or the like) into one; split i.e. burner body (comprising a combustion head, oil or gas systems), fans and combustion burner control system (including the control box, fan thermal relay, AC contactor, etc.) are each independent three-part system, according to the specific requirements of the boiler and user choice. Simple 8) should be used in construction, reliable operation, easy to adjust and control the repair, easy to implement automatic control of the combustion process in the burner. 9) to deal with the burner brand, performance, price, and service life of comprehensive comparison. 10) In addition to the burner air pressure to overcome the resistance of the boiler body considered, but also to overcome the resistance and flue gas economizer system.

The difference between oil-fired city fired boiler in belgium and gas boiler difference between oil-fired boiler fuel oil boiler and gas boiler is fuel (such as diesel, oil, kerosene, etc.), fuel gas-fired boiler to gas (such as natural gas, city gas, methane, etc.), depending on the boiler What fuel burning device called a burner, gas burner configuration called boiler gas boiler, oil boiler burner configuration called oil-fired boiler, oil-fired boiler and gas boiler difference lies in the use of fuel burners burn anything.

Battle blue horn sounded, emissions of sulfur, nitrogen and oxygen compounds gradually strict national requirements. To improve the quality of the environment, but also the people a blue sky, in all industries around the environmentally friendly product revolution, Hainan Sinochem Pharmaceutical companies are no exception. By the company investigation and comparison of city fired boiler in belgium products, in March 2017 signed a six-ton ​​steam-cleaning integrated condensing gas boiler and steam fast boiler. Tested and post feedback, the boiler equipment installation qualification, operating normally, and successfully passed the inspection by local quality inspection departments of the boiler.

Free Chat

About Us

Contact Us