Horizontal Type Oil Steam Boilers

Horizontal Type Oil Steam Boilers

Evaporation capacity is below 4t/h and 4t/h boiler. Check water level gauge, steam pressure gauge, feed water thermometer, exhaust thermometer, steam flow rate calculation. Oil temperature, oil pressure, oil level indication, oil quantity calculation, furnace outlet smoke temperature indication. The boiler should also have oxygen content of flue gas, negative pressure of furnace, economizer inlet and outlet water temperature indication.

Features 10 1 atmospheric horizontal type steam boilerss, hot water boilers controller computer, all the functions are stored on a magic smart chip, a key to power boilers, automatic timing, temperature operation, the user can set the start , shutdown time, the setup is complete, no special duty to save time, and effort. 2, the burner configuration imported brands, high degree of automation, automatic purge controller according to the instruction, the electronic auto-ignition, spontaneous combustion, air oil (gas) automatic ratio adjustment, security and stability performance, good combustion. And there are flameout protection device, ensure safe operation. 3, the inner fire tube inserted spoiler retardant, smoke slow speed, to strengthen the heat exchanger, the temperature of the flue gas discharged from a low smoke chamber, reducing heat loss and save fuel. 4, large font display temperature, easy to grasp and boiler operating conditions of the system, the water temperature can be freely set from 10 ℃ to 90 ℃, automatic boiler or heating system to provide users with life, bath with hot water. 5, the control system in accordance with the temperature control of boiler water circulation pump start and stop, boiler water circulating pump starts when the water reaches an upper limit temperature, lower than the hot water circulation pump stops when the water temperature lower limit. 6, horizontal fuel gas hot water boiler three return all wet back structure, using a large furnace, rough smoke tube design, increased furnace radiation heat absorption, the effective energy saving. Using threaded pipe and waveform furnace, greatly enhanced heat transfer effect, greatly saving fuel consumption. 7, while the machine is equipped with thermal protection (ultrahigh temperature furnace, the burner is automatically stopped and an alarm buzzer, the second over protection (the boiler shell temperature exceeds 105 deg.] C, the secondary circuit is automatically cut off), the lack of anti-dry protection of water (when water is lower than the low water level of the furnace, the boiler is stopped and an alarm beep), a boiler leakage protection (the control system detects electrical leakage, short circuit, automatically cut off the power) .8, according to the boiler pressure design , no pressure in the boiler state, there is no safety hazard .9, using advanced multi-layer insulation centrifugal glass wool, steel for packaging famous white color, heat loss, anti-rust appearance .10, gas heating boiler is widely used in homes, villas , hospitals, schools, hotels, restaurants, fitness center, bath center and other enterprises.

The latest was informed Tongling Municipal People's Government issued the "Notice on Tongling City to win the Battle of Blue Sky embodiment", as follows.

First, deepen industrial pollution control

Continuing to promote a comprehensive industrial pollution discharge standards, increase penalties and excessive joint disciplinary efforts, not discharge standards of the enterprise to suspend for rectification according to law. Implementation covering all stationary sources of emissions permits enterprise system, before the end of 2020 to complete the trade provisions of the license issued discharge permit management directory.

Carry iron and steel, cement, nonferrous metals, thermal power, coking, casting and other key industries and ports, shipping, coal-fired boilers fugitive emissions investigation, the establishment of management accounting, before the end of 2019 to complete the material (including waste) transportation, handling, storage, transfer and process fugitive emissions such as in-depth treatment.

Second, the continued implementation of the total coal consumption control, strict implementation of coal consumption reduction instead. By 2020 the city's coal consumption control in less than 13 million tons of coal accounts for the proportion of total energy consumption to decline further. Strict implementation of new coal projects coal reduction instead. Added support for the power industry outside of iron and steel, chemicals, nonferrous metals and other industries coal projects, the implementation of coal consumption reduction of 1.5 times alternatives. Increased focus on bulk coal remediation efforts. High-pollution fuel combustion zone ban bulk coal sales all clear.

Third, the implementation of the "coal to gas" and "electricity instead of coal." Strengthening the capacity of natural gas supply security, promote glazed tiles, casting and other industries natural gas instead of coal gasification project, orderly implementation of coal-fired facilities from coal to gas. Combined with regional and industry energy characteristics, and actively promote the implementation of "electricity instead of coal" in the field of industrial production, transportation, agricultural production, living and so on.

Fourth, continue to strengthen the supervision of the boiler. Consolidate the results of rectification of small coal-fired boiler, make sure the rebound does not occur, a citywide ban on new 35 tons of steam per hour and coal-fired boilers. Increase efforts to eliminate small coal-fired boilers. Dynamically updated list management coal-fired boiler, built-up area City 35 tons of steam per hour coal-fired boilers by the end of 2019 total phase-out or implementation of clean energy alternatives; retention of six chemical companies 2 130 tons of steam per hour of coal-fired boilers to complete all energy saving and ultra-low emissions transformation.

Fifth, strengthen the bulk coal governance. Strictly implement the "Interim Measures for commercial coal quality management" (National Development and Reform Commission Order No. 16) and technical standards for coal-fired boilers, in-depth implementation of bulk coal remediation crucial action, and strictly implement the ban on burning areas prohibit the use of high-polluting coal for fuel measures. To strengthen the management and control of coal-fired coal. Ongoing monthly coal quality sampling, and promote enterprises to increase coal-fired coal reform efforts.

PRODUCT INTRODUCTION fuel gas-fired boiler fuel gas-fired boilers and coal-fired horizontal type steam boilers is not the same, gasoline and diesel and gas-fired burner must be poured into the fuel to the boiler furnace using a combustion chamber rather than grate facilities. Since the fuel gas-fired boiler is not easy to cause the fly ash lit, so no oil or gas boiler slag removal equipment. If mixed with air or exterminate within a certain range, it is introduced into the furnace petrochemical and gas easily the explosive. Thus, any gasoline and diesel and gas-fired boilers must be selected and automatic combustion control system. Compact boiler fuel gas, and the small boiler exhaust, drainage, control and auxiliary equipment installed at the distribution panel, and produce large and small boiler assembly. Fuel gas-fired boiler safety valve installation key point describes the installation of fuel gas-fired boiler safety valve sure to carry out in accordance with reasonable installation process, to prevent wrong and lead to risk. Fuel gas-fired boiler safety valve installation should pay attention to what matters? The following is a brief description: 1 oil-fired boiler safety valve having a lever bar to avoid self-weight and the mobile device guide body defining deviant lever, the spring valve lift handle and avoid the need for screw adjustment means random twist. 2. Rated evaporation than 0.5t / h gas boiler safety valve should be arranged at least 2, Rated evaporation gas boiler should be equal to or less than 0.5t / h, fitted with at least one safety valve. Separable economizer outlet and a steam superheater outlet valve should be installed. Sectional area of ​​the connecting pipe between the boiler safety valve 3. Fuel gas boiler can not be lower than the imported cross-sectional area of ​​the valve. If several valve mounted on each stub is directly coupled to the drum, the passage sectional area of ​​the stub is less than 1.25 times not all of the area of ​​the exhaust valve. 4. Oil and gas boiler safety valve should be mounted vertically in the height of the boiler drum and the header. Can not be mounted between the valve and the steam outlet conduit and the valve drum or header. 5. For rated steam pressure less than or equal to 3.82MPa boiler safety valve throat diameter of not less than 25 mm; the rated steam pressure is greater than 3.82MPa boiler safety valve throat diameter of not less than 20 mm. 6. Fuel gas boiler safety valve should normally be established an exhaust pipe, the exhaust pipe should be directly connected security grounds, and there is sufficient cross sectional area to ensure the smooth flow of the exhaust gas. The bottom of the valve should be equipped with an exhaust pipe connected to the drain of a safe place. Valve must not be installed in the exhaust pipe or drain pipe.

Free Chat

About Us

Contact Us