To get industrial gas boiler safe operation must be done to check the work of industrial gas-fired boiler pressure vessel belongs, in our country there are strict and clear standards of production and operation. In particular boiler in operation, should always pay attention to whether the safe operation of the boiler, auxiliary equipment and operation of each respective instrument valves is stable. Therefore, gas wns automatic fired steam boiler room is necessary to establish a sound system of inspection tours and boiler room equipment maintenance system. First, natural gas boiler room mobile inspection system 1, in order to ensure the normal operation of the boiler and its accessory equipment, timely detection of problems, fireman on duty personnel at least once every half hour tour inspection. 2. Check gas boiler burners, pressure gauge, thermometer, circulation pump, water supply pump, water softening, safety accessories, an instrument, secondary instrument is functioning properly. 3, check whether the abnormal changes in various types of signal lights. 4, check the water level in the tank gas boiler, feed pumps, circulating pump and motor bearing temperature and pump lubricating parts are normal. 5, check the position of the gas valve and the steam boiler feedwater pressure switch valve is normal. 6, mobile inspection found problems in time, and test results recorded in the log boiler and accessory equipment inside. Second, gas-fired equipment maintenance system 1, two gas-fired boiler on the pressure gauge value is not the same timely maintenance, to ensure reflect the actual operation of the boiler pressure. 2, gas boiler pressure gauge damage, when the dial is not clear, timely replacement. 3, rotating machinery lubricating oil passage remains open, the oil cup to maintain a certain oil level. 4, run, run, drip, leak repair valves can be repaired, replaced. 5, inspection, maintenance and feed pumps, circulating pumps and pump valves open is flexible, single-stream if the door is closed tight. 6. Check the gas-fired secondary instrument is normal. 7, to remove dust on the equipment and the accessory device. 8, check the gas boiler safety valve manually turn on the water after closed trials are tight. Automatically turn on the water, blowing off steam at least once a week. 9, pressure gauges operate properly flushed at least once a week. Trap maintenance once a month. 10, over-temperature, overpressure alarms, overpressure interlock device checks at least once a month, and maintenance. Gas boiler pressure gauge, water level gauge and a safety valve are the three safety accessories on the gas steam boiler, with particular attention.

Why supervisory inspection-free wns automatic fired steam boiler steam boiler characteristics can exempt? According to the "Steam Boiler Safety Technology Supervisory Regulations" provides that the normal water level of boiler water volume less than 30L in the boiler does not belong to the scope of the surveillance. When the normal water level of boiler steam boiler water volume is only 27L, like installing a home water heater as safe. So steam boilers belong to exempt boilers. You can avoid the security of small steam boiler What are the benefits? 1, you can not build a separate boiler room, can be placed in the basement, roof and other places 2, do not have a full-time duty Boilermakers (conventional boiler requires certified fireman) 3, eliminating the need for a year dealing with government departments, burning more peace of mind coal steam boiler What are the advantages over conventional steam boiler? Coal-fired steam boiler, is lower than conventional coal-fired steam boiler safety running costs, fast start, no registration and annual inspection, firing five minutes produce steam. Coal-fired steam boilers suitable for use in what place? It can be used in hotels, factories, hospitals and other occasions. The hotel can be used as a steam boiler steam laundry places, canteens and other uses. As plant steam for a steam boiler may be used in the process. Steam boiler can be used as a hospital to disinfect hospital use. Free supervisory inspection characteristics steam boiler: The supervisory inspection-free steam boiler water volume is less than the normal water level 30L, within the exemption permits boiler use a range of countries that use the certificate without going through the boiler. Furnace is equipped with a built-in separator, to solve the problem with the water vapor, more to ensure the quality of design, high degree of automation, personalized steam, all programs are concentrated on a button, extraordinary fool fuzzy control, each operator convenience. Boiler operating system using automatic intelligent electronic control system for the automatic control of all operating states can glance. You can observe in the display to the boiler work state, state boiler water level, steam pressure state level, pump operation status, fault alarm status, allowing you to keep abreast of boiler operating conditions, use more confidence. Using high-quality components all piping and instrumentation connections are made of stainless steel or copper pipe connections, electrical appliances are the most well-known of West Germany Electric, safe and reliable, luxuriously equipped. Multi-chain security features. Products fitted with a boiler inspection by checking the safety valve, pressure controller overpressure protection against boiler due to excessive pressure caused by the explosion; as well as low level protection limit, the boiler will stop automatically in case the water supply is stopped to prevent the phenomenon of dry boiler electric heating element damage even lead to burnout. Leakage protection so that safety of operating personnel and equipment more secure, even when a short circuit caused by improper operation of the boiler, the boiler will automatically cut off the circuit if leakage current and timely protect the operator and control lines. Easy to install, easy to use products factory have passed strict debugging, users only need to connect the power supply and water, as long as the boiler to fill the fuel inside the boiler to enter the automatic running state, without complicated installation. Scientific design, beautiful appearance cabinet scientific design, internal design structure is reasonable, maintenance is extremely convenient. Boiler shell CNC CNC cutting and hemming a molding process, work fine; shell surface temperature after spray treatment, durable, aesthetically pleasing appearance. The main feature of the supervisory inspection-free steam boiler 1, for a wide range of environmental protection, in line with environmental requirements; 2, economy using the latest energy saving technology can save about 50% of the monthly cost of using highly efficient thermal insulation materials, heat loss is very low fuel savings; 3, having a water safety, overpressure, over temperature protection features, safe and reliable; 4, simple practical boiler structure, small size, easy installation and maintenance, long life; 5, convenience can select any number of automatic computer-based digital display phenotypic two kinds of control, easy to operate, less failure, easy to use; 6, adjustable load can be adjusted as desired within the rated range; 7, this series boiler has 0.4MPa (4 kg), 0.7MPa (7 Gongjin), 1.0MPa (10 kg) of three kinds of steam pressure, steam production from 30KW to 2160KW a total of 27 kinds of specifications models for users to choose according to the needs, can also be custom designed for specific users ; coal, oil, electric, gas steam boiler applications: washing ironing industry: dry-cleaning machine, dryer, washing machine, dryer, ironing machine, iron and other packaging equipment for use Machinery Industry: labeling machines, standard sets of supporting the use of Biological Chemical Industry: supporting a fermentation tank, reactor, sandwich pot, mixer, emulsifier and other equipment used in the food industry machinery: tofu machine, the steam box, sterilization tank, packing machine , coating equipment, sealing machine and other equipment for use in other industries :( oil, automobile) steam cleaning industry (hotels, dormitories, schools) steam or hot water supply, (bridges, railways) concrete curing and so on. Steam boiler steam moisture content too much harm.

Cade Shopping Mall is located in central Shanghai Hongkou District, Shanghai Daily larger flow of people in the region. The introduction of Shanghai air pollutant emission standards, boiler flue gas emissions of nitrogen oxide emissions to less than 80 mg / m, Shopping Mall a coal-fired boilers have been used for many years, NOx emissions far super to this request, the urgent need to replace more environmentally friendly low nitrogen emission boilers. Other units through the use of fast Boiler introduction and understanding, determined and fast boiler to achieve cooperation, party fast to their specific needs to recommend one condensing gas hot water boiler of a 4.2MW for heating needs of the shopping center.

Steam boiler pressure gauge should pay attention to matters 1. The rated steam pressure less than 2.45MPa wns automatic fired steam boilers, pressure gauge accuracy of not less than 2.5; equal to the rated boiler steam pressure 2.45MPa, the pressure shall not be less than 1.5. Electric heating boiler and the boiler is mainly composed of electric control box and control system. Its characteristics are environmentally friendly, clean, no pollution, no noise, automatic, with limited energy and reduce prices significantly, as a new boiler electric heating boiler equipment increasingly being recognized. Electric heating the core member is electrically heated boiler, directly determines the life of the boiler, to select a non-metallic electrical heating tube (such as a ceramic heating pipe), because it is resistant to the load, a long life, and a water separation structure, the boiler Wing no leakage. There are heating and hot water boiler bath for two purposes. Hot water boiler by circulating hot water circulation pump hot water holding tank, the tank hot water heating cycle can be achieved bath object; hot water boiler by circulating hot water circulation pump heating conduit, through the heat sink (radiator) people can achieve heating requirements; hot water boiler and hot water circulating pump with heat exchanger can be achieved bathing and heating dual function. Dial gauge diameter of not less than 100 mm, to ensure that the operator can clearly see the surface pressure indication. 2. On the dial gauge steam boiler should draw a red line to indicate the maximum allowable working pressure. 3. The steam boiler pressure gauge should be installed in place to facilitate the observation and purged, and should prevent high temperature, vibration and icing. 4. The steam boiler pressure gauge should be checked at least once every six months, to be sealed lead-sealed after calibration. 5. The steam boiler gauge connection tube not leak water and steam, otherwise it will reduce the pressure instruction value. 6. A steam boiler pressure gauge measuring range should be compatible with the operating pressure of the device under test, the working pressure is generally 1.53 times, preferably 2 times the working pressure. Steam boiler no pressure gauge, pressure gauge or pressure gauge damage does not meet the requirements. When the steam boiler pressure gauge of the following circumstances, should stop using: 1. The surface of the glass or the dial pins; Lead seal, lead seal is broken or exceeds the calibration period; when no pressure gauge pointer position is limited to the limit staple nail can not be restored, and the rank unlimited gauge pointer movement from zero data is out of range pressure layer. Poor; leak or pointer jitter in the meter; other defects affect the accuracy of the pressure gauge. The use of the accumulator: the accumulator for a hydraulic system of the machine intermittently. It may be a low speed motion or intermittent motion of the actuator, the oil reservoir of the hydraulic pump, when rapid movement of the actuator requires a large flow rate, as an auxiliary energy supply to the system together with the hydraulic pump, enabling the pump and the entire hydraulic system miniaturization, to achieve energy saving. Hydraulic shock absorber valve and the opening and closing of rapid mutation load, the system generates a pressure shock, loved one causes vibration and noise and even damage the machine. The accumulator can relax and absorb the impact pressure of the liquid. Accumulators absorb and reduce the pressure pulsation flow pulsation and various hydraulic pumps, thus reducing noise and vibration system. The function of the gas spring having a damper, the vibration can be used to walk between the car body and the wheel and other mechanical absorption. The accumulator may be balance gravity vertical actuator (hydraulic cylinder) and the potential energy absorbing load drop into hydraulic energy storage, while producing speed resistance. When the rising vertical actuator, the accumulator absorbs energy of the original release, and together with the oil pump to the hydraulic cylinders, so as to achieve balance and energy.

Free Chat

About Us

Contact Us