2 Tons Gas Steam Boilers Selection

2 Tons Gas Steam Boilers Selection

Matters needing attention in loading and installation of Gas-fired Steam Boiler

Gas-fired steam boilers are a very wide range of special equipment, usually built in boiler rooms. However, in the process of loading and installation, some problems must be paid attention to, otherwise it may cause a certain degree of economic loss.

1. Pay attention to the following matters during the loading and unloading and handling of gas-fired boilers: the lifting capacity of the lifting equipment should match the weight of the lifting boiler. The lifting lug on the boiler with the lifting lugs that cannot be used for lifting can not be used for lifting. The length of the steel cord should be reasonably selected to avoid the scratching of the furnace due to the improper length of the steel cord. The boiler must be protected from any damage during handling and handling.

2. Reserves for maintenance space When installing boilers, ensure that there is sufficient maintenance space around the boiler.

3. Setting and precautions for the base and base of the gas steam boiler The boiler body must be installed on the basis of 100-150mm above the floor of the boiler room. It must be confirmed with the technical personnel of the boiler manufacturing company in advance and constructed according to the basic drawings. The anchor bolts must be reserved on the foundation. The foundation shall be capable of withstanding the maximum weight of the boiler and the amount of water it holds. When installing the base, you must first position it. After positioning, adjust to the same length of the two diagonals of the base, and then tighten all the fixing bolts. The installation of the base is carried out with reference to the reference line.

4, general precautions Be careful not to tilt and impact the boiler and accessories too much. No combustibles can be placed around the boiler. Do not use oil and water to smother the boiler. The boiler should normally be installed in a separate boiler room. The new gas-fired boiler room should not be connected to the house. The boiler room shall not be connected to Class A, Class B and Category C fire hazard rooms using flammable liquids. If connected to other production plants, the application firewall is separated.

What fans need to pay attention when installing? Speaking boiler, many people are no stranger to the north of our country will carry out most of the local use, and has many different varieties, each variety in the use of the process, there will be detailed information must be different, we We can go right to focus attention later in the selection process will be easier. Now let's see, what breed detail what we are? In accordance to the usefulness of the classification, it can be divided into power boilers and boiler heating boilers. Power boiler includes power plants, boilers and ship boilers and so on. Heating boiler even more widespread use, mainly the use of hot air and the heating medium, which can give the corresponding steam and hot water. Different purposes pot myself, on practical local will be very different, it can correctly be recognized, which is to ensure the future use of the conditions. In accordance with the way the use of fuel, the boiler can be divided into three coal-fired boiler, oil-fired boiler and gas boiler. Each of the different varieties of the boiler, he will be different from the use of carriers and burning way, and now gradually exit the mall coal-fired boilers, gas boilers more and more. Otherwise the process of burning coal more environment, and the gas we can bring more security in the use of time will become more environmentally friendly, they have been using more local. Boiler fans in the process of the device, some jobs are we bound to be noticed, this is a very important job for the entire use of it, then in the process, what the job requires extra attention to detail are the way What is the real situation to understand these aspects, what about our device will be more jobs for the guarantee. In general, carefully read the instructions boiler fan, detailed way the device has a full understanding, in particular, to look at the left rotation or right rotation, the side we faced is extremely important. Throughout the process, the direction is very important, not Ann who, otherwise there is no way to normal operation and perhaps bring some impact. Process equipment in the boiler fan, but also to find the right position, the boiler there may be different on different orientations of the device. In the flue outlet and the convergence of local, you can correct a device before you can have a better use. Process device, combined with the actual situation at the scene, a professional staff, that there will be more benefits for the entire device. Boiler fan device is not difficult, just in the process of the device, carefully read the instructions, and you can find a detailed orientation, so that it can be better to play a role, is using is the most important. Some people in the process of the device, perhaps not particularly clear, after so they picked the wrong orientation and direction appear, then it will bring about the use of relatively large trouble. After the device before it can play a good role, but does not affect the use of the future, which are crucial for people.

To introduce 2 tons steam boilers selection pressure gauge and hydraulic press accumulator using steam boiler pressure gauge should pay attention to: 1, rated steam pressure is less than 2.45MPa steam boiler, the accuracy of pressure gauge must not be 2. 5; Rated steam pressure large or equal to 2.45MPa boiler, pressure must not be less than 1. 5 class. The diameter of the dial of the pressure gauge shall not be less than 100 mm to ensure that the operator can see clearly the surface pressure indicator value. 2. A red line should be drawn on the pressure dial of the steam boiler pressure gauge, indicating the maximum allowable working pressure. Steam boiler pressure gauges should be installed in a place that is easy to observe and wash. 4. Steam boiler pressure gauges should be checked at least once every six months, and should be sealed with lead after calibration. 5. Steam boiler pressure gauges should not have leakage of water and steam leakage in the connecting tubes of the pressure gauges of steam boilers. (4) the steam boiler pressure gauges should be checked at least once every six months and sealed with lead. 5. Otherwise, the pressure indicator value will be reduced. 6. The measurement range of the steam boiler pressure gauge should be adapted to the working pressure of the measured components, usually 1.5 times of the working pressure, preferably 2 times of the working pressure. Steam boiler does not have pressure gauge, the pressure gauge is damaged or the installation of pressure gauge does not meet the requirements, steam boiler pressure gauge should be stopped when one of the following conditions: 1, broken surface glass or dial calibration mold There is no clear paste; 2, no lead seal, lead seal damage or beyond the calibration period; 3, without pressure, the pressure gauge of the finite pin can not be restored to the limit pin, the infinite position of the gauge pointer deviated from zero data beyond the allowable pressure clothing; 4, gas leakage or pointer jump in the meter; 5, other defects that affect the accuracy of the gauge. Purpose of the accumulator: the accumulator is used in the hydraulic system of intermittent machinery, which stores the oil output of the hydraulic pump during intermittent or low-speed movement of the actuator, and when the rapid movement of the actuator requires a large flow rate, As an auxiliary energy source, together with the hydraulic pump, the oil pump is supplied to the system, thus the oil pump and the hydraulic pump are realized. The miniaturization of the whole hydraulic device absorbs the quick opening and closing of the impact hydraulic reversing valve and the sudden change of the load. The system will produce shock pressure, the darling will lead to vibration and noise, and even damage the machine. The accumulator can mitigate the impact pressure absorption pulsation of these fluids absorb and reduce the flow pulsation and pressure pulsation of various hydraulic pumps thus reducing the system noise and vibration. The damped accumulator acts as a gas spring and can be used to absorb the vibration between the fuselage and wheels of walking machinery such as vehicles. The balanced accumulator absorbs the gravitational potential energy of the vertical actuator (hydraulic cylinder) and its load as it falls. When the vertical actuator rises, the accumulator releases the original absorbed energy and supplies oil to the hydraulic cylinder together with the pump, thus realizing the balance and energy saving.

Fast boiler particularly strong technical team, they listened carefully to our needs and give us tailored technology solutions, from boiler production, transport to the site installation and commissioning took only 35 days time, all aspects of the deal in place, the boiler quickly it is put into use. --customer feedback