20T Oil Fired Steam Boiler

20T Oil Fired Steam Boiler

The electric boiler, also known as the electric water boiler, the electric drinking water boiler, the electric tea boiler, and the electric tea stove, is divided into two types: continuous electric water boiler and split tank electric water boiler, which are designed to meet the needs of more people drinking boiled water. A kind of drinking water equipment using electric energy to produce hot water is developed, which is mainly suitable for the use of schools, hospitals, factories, supermarkets, shopping malls and other population-intensive units. The main component of the electric water heater is the electric heating tube which plays the role of heating. It is better to choose the electric heating tube with insulating material, which has high safety factor and long service life. Under normal conditions, it can work for 6-7 years. The electric hot water boiler is also called the electric heating boiler, the electric bath boiler, etc. The electric hot water boiler is the production hot water that adopts the latest electric heating technology and the control system design, satisfies the heating or the supply life, Fully automatic environmental protection boiler of hot water for bath. This kind of boiler is suitable for hot water and heating in hotels, villas, factory buildings, office buildings, government agencies, colleges and universities, hospitals, troops and other places with high appearance requirements. The electric boiler is divided into two types: direct heating type electric boiler and regenerative type electric boiler. As the name implies, the direct heat type electric boiler is no longer explained here, and the regenerative type electric boiler is based on The power sector encourages electricity heating during trough periods and enjoys preferential electricity prices, introducing a new, efficient and energy-efficient electric heating product. Regenerative type electric boiler is composed of heat storage water tank and auxiliary equipment, which makes use of hot water heating in heat storage tank to achieve the goal of using all or part of the low valley power from the purpose of making use of the hot water in the heat storage tank. Electric 20t fired steam boiler is also called electric steam boiler. Electric steam boiler is a steam boiler which uses power source to heat and produce rated pressure. Steam boilers can be used in textile, printing and dyeing, paper making, food, rubber, plastics, chemical, pharmaceutical, iron and steel, metallurgy and other industrial products processing process Steam is required and can be used for heating, bathing, air conditioning and hot water in enterprises, institutions, hotels, schools, catering, and service industries.

01. The reason why the ignition rod of gas-fired boiler burner does not ignite: 1. There is carbon slag in the gap of the ignition rod, there is oil pollution. 2, the ignition rod is cracked. Damp. Leakage. 3. The distance between the ignition rod is not right, too long or short. 4, the distance between the ignition rod is not right, it is too long or short. 4. Ignition rod insulation outer skin is damaged, short circuit to the ground. 5, ignition cable and transformer failure: cable broken, connector damage caused by short circuit fire; The transformer is out of line or out of order. Gas-fired boiler burners failure, ignition rod non-ignition treatment measures are as follows: clear, replace, adjust distance, change wire, change transformer. Second, the reason why the ignition rod of the gas-fired boiler has sparks but does not ignite: 1. The ventilation clearance of the cyclone disc is blocked by carbon deposition and the ventilation is poor. 2, the oil nozzles are unclean, clogged or worn. 3, the setting angle of the air door is too small. 4, the distance between the tip of the ignition rod and the leading edge of the oil nozzle is inappropriate (too prominent or indented) 5, The solenoid valve of the first oil gun is blocked by debris (small fire gun) .6, the oil quality is too viscous to flow or the filtration system is clogged or the oil valve is not opened, which causes the oil pump to absorb insufficient oil, the oil pressure is low. 7, the filter of the pump itself is blocked. 8, Oil contains more water (boiling noise in heater). The measures to deal with spark but not ignition of ignition rod of gas-fired boiler are as follows: clearing; cleaning first, if no replacement; adjusting test; adjusting distance (3~4mm is good); remove cleaning (cleaning parts with diesel); check pipes and oil filters, insulation equipment; remove oil pump outer screws, carefully remove the outer cover and remove the inside net, wash with diesel; replace it with new oil. Third, when a small fire of a gas-fired boiler is turned into a fire, the reasons for its extinction or flickering instability are as follows: (1) the air volume of the air outlet of the fire is set too large. 2, The oil valve fretting switch (the outermost group) of the fire is improperly set (set higher than the air flow of the fire valve) .3, the viscosity of the oil is too high and not easy to atomize (heavy oil). 4, the distance between the cyclone disc and the nozzle is inappropriate. 5, To wear or soiled the nozzles of a fire. 6.The heating temperature of the reserve oil tank is too high, causing the steam to cause the oil pump to send oil unsmoothly. 7, the oil in the burning oil and gas hot water boiler contains water. Treatment measures to extinguish or flicker unstable when small fire of gas-fired boiler turns to fire normally: reduce test step by step; raise heating temperature; adjust distance (between 0~10mm); clean or replace; set about 50 ℃ or so; change oil or drain water. 4. Causes of noise increase in gas boiler burners: 1, shut-off valve or insufficient oil intake in the oil path, blocking of oil filter. 2, low inlet temperature, too high viscosity or too high intake temperature of pump. 3, oil pump failure. 4, oil filter blocking. 4, oil inlet temperature is low, viscosity is too high or pump inlet temperature is too high. 3. Fan motor bearing Damage. 5, fan impeller is too dirty. Treatment method for increasing noise of Burner in Gas-fired Boiler: (1) check whether the valve in the pipeline is open or not, and the oil filter is working normally. Cleaning pump itself filter screen. 2 oil heating or lowering oil temperature. 3 replacement pump. 4 replacement motor or bearing. 5 cleaning fan impeller.

01: the greatest benefit of economic use of gas-fired steam boilers is that they can save large amounts of material costs for enterprise users, without the need to spend heavy money on large amounts of coal-carbon fuel. Only clean natural gas can be used to burn and release the steam used. Natural gas can also increase the thermal effect and reduce the cost of material input for users. Safety: natural gas is well known as one of the safest non-toxic and pollution-free clean fuels, unlike liquefied gas or gas leaks that precipitate on the ground and even cause accidents. Gas-fired steam boiler is the safest way to choose natural gas in the process of transporting gas, and it is easy to leak. Being found to be used is therefore the safest way to use it. 3: the convenient gas-fired steam boiler is also the most convenient one in use, so it will be favored by the customers of various enterprises. Natural gas pipelines are as convenient as tap water for domestic use, and sustainable use will not be bothering you. It eliminates the cumbersome work such as transporting or stacking coal and cleaning coal residue. 4: clean gas-fired steam boilers are highly rated in the market because they are clean and clean in use and free of black pot bottom and exhaust gas pollution. So it's cleaner than any other boiler in use. One way, whether directed at operational work or surrounding residents or the business itself, can be cleaner without compromising physical and mental health.

Fangkuai Boiler is based on low-nitrogen energy-saving and environmental protection. It focuses on the development trend and uses universal excellent technology, products and services. According to such a method, it is now applicable to the development of society around the world, promotes cutting-edge work in the future manufacturing industry, and maintains the ideal use of customers in various industries.

Steam boiler preventive measures introduced Common Failures and precautions 20t fired steam boiler and steam reciprocating pump 1. Biomass boiler is a kind of boiler to biomass energy as a boiler fuel called biomass boilers, steam boilers into biomass, biomass hot water boiler, biomass stove, biomass thermal oil heaters, vertical raw biomass boilers, biomass boilers and other horizontal. Fuel gas boiler is not only fuel but also refers to the gas boiler. Previously no such dual-fuel boiler, burner because either fuel or gas, no dual fuel burners. With the rapid development of the world energy equipment, some European countries begin production and sales of fuel gas burner, dual fuel burner and boiler combination of organic birth of a new breed of boiler - fuel gas-fired boiler. Near the steam boiler room should be equipped with adequate and effective fire fighting equipment. 2. Steam boiler room must have staff on duty 24 hours, the guards take turns, and always check the water level in the boiler, in order to ensure that it is above the safety line to prevent an explosion caused by burning dry. If the fire operation in explosive areas must obtain a work permit fire and take adequate fire safety measures in order to carry out fire work. When the fire should send someone on duty at all times observe the fire situation. 3. A storage vessel containing the non-flammable gas in the boiler room. 4. The staff of steam boiler room must be certified before the arrival of the boiler and proficient technique, it has a certain capacity to detect and recognize security risks. 5. If the boiler safety on a regular basis in accordance with the boiler maintenance procedures, should be carefully examine each of insecurity in the inspection process. 6. Distribution Line steam boiler room disposed defective safety device using a metal tube or pipe nonflammable hard plastic protection switch box should be installed outside the boiler room, respectively, to achieve power, should be prohibited. 1. What is the reason there is no discharge of steam reciprocating pump is? How, how? A: (1) Failure: 1 suction or discharge pipe blockage. (2) out of the stuck valve. There is an air cylinder. (4) a suction tube connected lax. (5) column (live) seriously damaged piston ring. (2) Method excluded: (1) exclusion of pipe blockage. (2) Remove the inlet, the outlet valve on the plug. (3) filled with water, the air is discharged. (4) fastening the pipe. (5) Replace Column (live) piston ring.

When the gas 20t fired steam boiler installation is complete, you should first check whether the internal boiler tidy and clean without foreign body, and then close the manholes and valves. Oil (gas) pipeline, and the return line of compressed air to blow the pig debris, and then connect the burner fuel supply port, check the connection is tight, then a predetermined pressure test.