Two Ton Gas Boiler Capacity

Two Ton Gas Boiler Capacity

Shandong textile mill electric steam two ton boiler capacity how much the current price in many textile mills in Shandong region or to steam boilers for production of electricity. Because the local gas is not very adequate, resulting in a lot of companies do not have access natural gas, but is also required by environmental policy. So, for Shandong textile enterprises, the only use of electric steam boiler production. Recently, there is a textile enterprise in Shandong consult with fast boiler need to purchase an electric steam boilers for production, but for specific models and prices are not aware of. Boiler manufacturers need help accounting models and prices. In this regard, fast boiler according to the actual situation of the textile business accounting, concluded that the plant with electric steam boiler 2t is possible. Current procurement costs of around 20 million.

Dairy production and processing sectors, need a lot of steam on food drying, sterilization, stereotypes, such as processing, steam two ton boiler capacity essential. Xinjiang Ake Su Xinnong Dairy Co., Ltd. as a local brand, has a large market users. 2016, Akzo increased demand for dairy production, the original steam boiler company can not meet today's production needs. In the same year, Akzo dairy cooperation with our company, signed a series SZS 6 tons of steam pipe steam boilers, steam support for the dairy industry dairy production Aksu.

New coal fire late, often appear off the fire bed fire, fire away from coal gate about 0.6 ~ 1.Om, burning furnace is not strong, high ash carbon content. For existing furnace arch structural problems, from improving fuel fire conditions, improve furnace temperature begin to transform the two ton boiler capacity. After the furnace arch after the transformation, the people stove fuel from coal gate 0 · 3mRP fire, the fire bed combustion intense flame full of good, strong rotation. Since lowering the front arch, the arch extended, reduced to about 1 2 throat formed between the arch of the original pitch. Where the enhanced mixing flow disturbances, reorganized stream, enhanced combustion furnace, to effectively improve the temperature of the entire front region and the arch of the furnace, to reach 1400 degrees, the condition of the fuel to improve ignition. 2. The ignition point of coal in advance, the temperature of the furnace to improve the ash carbon content decreased. Smoke swirling mix and strengthen the separation of coke particles in the flue gas, so that it falls on the fire bed and the new layer further fuel burn. Flue gas also strong swirl in the flue gas CO, H2, CH4 and other combustible combustion gases, thereby improving the thermal efficiency of the boiler is more than 4%. But also improve the boiler output to meet the needs of the production of steam, reducing environmental pollution, expanding the scope to adapt varieties of coal.

Method of reducing the exhaust gas temperature of the two ton boiler capacity which: standard boiler exhaust gas temperature: between the boiler flue gas temperature of 200-230 deg.] C in accordance with conventional design national standard thermodynamic calculation boiler design requirements. Conventional exhaust gas temperature selected reasons, coal fired boiler combustion process will produce a certain amount of SO2, and SO2 below 170 ℃ will bind and generating flue gas H2O H2SO4 sulfuric acid, H2SO4 sulfuric acid and will form boiler heating surface of tail corrosion, thereby reducing the life of the boiler, conventional coal-fired boiler exhaust gas temperature is higher than 200 ℃. Temperature is high energy loss and more, is not conducive to energy saving. Cooling measures taken to ①, the economizer application: increasing the boiler economizer (economizer) of heat transfer area, larger than the conventional take about 1-2 times the flow cross sectional area economizer structure, effectively reduce smoke flow rate, to strengthen the heat transfer efficiency, reduce exhaust gas temperature; ②, air preheater applications: pipes connected to the air preheater economizer disposed, the apparatus can effectively increase the temperature of the combustion air, improving the ignition of the fuel condition. Very beneficial to the boiler combustion conditions. ③, adjust bidirectionality combustion system, a boiler originally designed for fuel specifications have some flexibility, different media in effect outside the combustion process are different, adjusting the embodiment, with the economizer and the air preheater using, the temperature of the boiler exhaust emission control at a suitable temperature, that make full use of heat energy, but also to ensure the integrity of the structure and function of the relative equipment, environmental protection, energy saving, security and development is the social responsibility of all of us for a rational design of industrial structure boiler, thermal efficiency is relatively high, its emissions would be relatively low temperatures, so we must be careful when choosing a boiler boiler property report form.

Free Chat

About Us

Contact Us