10 Tons Wet Back Gas Fired Boiler

10 Tons Wet Back Gas Fired Boiler

Method for safe operation of steam 10 tons wet back fired boilers steam boiler before use, must be checked for damage of the insulating layer, to check the burner is operating correctly, and to check the position of the opening degree of the valve to ensure it is correct. Must be checked for automatic control instruments and equipment safety equipment accessories, equipment, in order to comply with the requirements. Check item prior to ignition of the steam boiler: open valve before oil circulation pump, oil heating valve is opened, adjusted reasonably high level of the tank, the gas pressure is determined before the natural gas burner ignition must be within the range, the power good . Refers to the operation of the steam boiler is refluxed pressure activated device circulating pump, the circulating pump outlet, inlet, outlet, and the system, it is in the normal range. Circulation pump run for 30 minutes. After the stability of the system, the next step. Open the gas tube steam boiler manual valve, button start-up burner, natural gas burner into the furnace, and then the ignition, the flame remains stable, i.e. is in a safe operating condition. In the firing process steam boiler, if you accidentally quenching phenomenon occurs, the device will automatically interlock burner saver appear. It must be promptly cut off the natural gas pipeline to start the furnace purification. Replacement of the residual gas in the furnace and closed. The system load requirements, temperature requirements and thermal oil outlet, the burner can automatically adjust the size of the fire source.

Low nitrogen 10 tons wet back fired boiler technology made a major breakthrough, however gratifying that through the unremitting efforts of domestic boiler companies, China's low-NOx combustion technology gradually into the world advanced list, catch up with a lot of foreign advanced technology.

6 tons adjusting a combustion gas steam 10 tons wet back fired boiler, normal combustion boiler three basic aspects of indicators include a uniform supply of the fuel, reasonable ventilation, adjustment the combustion. 1, to maintain the high temperature of the combustion chamber temperature of the upper layer is preferably in the 1100 ~ 1300 ℃, flame orange in color. Flame reddish color indicates that the amount is not enough to the wind, the color white indicates that excessive wind. It should be appropriately adjusted. 2, fuel ash to reduce ash content in the combustibles to be below 10%. 3, reducing the temperature of the boiler flue gas exhaust gas temperature should be controlled below 200 ℃. 4, holding furnace negative excess air boiler is 1.2 to 1.4, by adjusting the balance of the blowers to maintain the furnace pressure is -20 ~ -30Pa. 5, the thermal efficiency of the boiler to improve the thermal efficiency of the boiler should be kept above 60%. II. Combustion Adjustment 1, the amount of fuel to air required for combustion and the amount of a reasonable distribution. Ventilation should first increase the amount of fuel increases, it should first reduce the amount of fuel supply reduced ventilation. 2, the thickness of the seam and seam thickness configuration grate speed is 80 ~ 120mm grate speed at high, middle and low profile configuration of several commonly used methods:. 9a rapid combustion of thin seam b c thick seam in low combustion. 3 thick seam combustion speed, the segment with the wind blowing principle: burn promoting intermediate ends. That is, after the coal into the coal starts to warm up the shutter, fire line front arch, the primary combustion zone, the middle grate to burn the rear grate zone. Normal combustion conditions are: fuel from the coal at the beginning of the fire shutter 300mm, uniform flames, the fire bed formation, at the end of combustion from the end of the grate 300 ~ 500mm. 4. maintain proper furnace temperature to avoid coking. The fire bed to maintain the homogeneous combustion, to avoid burning fire bed obliquely. 6. The residence time of the fuel on the grate in less than 30 minutes.

Henan 10 tons wet back fired boiler manufacturers fuel gas combustion boiler features a contrast, combustion of fuel is a liquid fuel and fuel oil, its boiling point is always lower than the ignition point, so that fuel combustion is always performed in the gaseous state. Fuel oil particles atomized by the jet into the furnace after the furnace is heated by high temperature flue gas, gasification, and hydrocarbon ambient air encounters the oxygen gasification, a flame. Heat produced by combustion of oil particles pass a part of the gasification and combustion of oil particles continuously, until the burning ember. The smaller the diameter of oil particles, the faster the combustion of oil particles. Similarly, the oxygen required for combustion of oil particles can be supplied in time, the combustion of oil particles can more quickly. Therefore enhanced combustion of oil must do the following: 1, to improve quality of atomization, the oil particle diameter is reduced; 2, increasing the relative velocity of the air and oil particles; 3, reasonable air distribution. Second, the combustion gas boiler manufacturers Laid Henan boiler ignition gas with a high calorific value, large amount of air, can make the combustion gas, a large amount of air mixed therewith. No fuel combustion gas atomization process with the gasification process. Gas and air mixing mode, the flame length and flame temperature has a significant impact on the intensity of the combustion. Depending on the mixed mode, the combustion method of the boiler manufacturer Henan gas boiler can be divided into three types: 1, i.e., this method does not pre-mixed combustion diffusion combustion, but interdiffusion gas nozzle opening, and burned. Shao Shao stability advantages, the structure of appliance is simple, but the flame is longer, easy to produce incomplete combustion and carbonization of the heated area. 2, partially premixed combustion air prior to combustion such a way that the combustion of part of the air mixed in advance with the gas (primary air excess coefficient between 0.2-0.8), followed by combustion. The advantage is clear combustion flame, combustion strengthened, high thermal efficiency. However, combustion instability, and high combustible component of the control primary air requirements. The gas burner usually used such combustion. 3, i.e. flameless combustion air which has been uniformly mixed with the combustion gas prior to such gas required for combustion. Primary excess air ratio is equal to the excess air ratio for complete combustion of the fuel required to obtain oxygen from the ambient air during the combustion process. When the combustion gas and air mixture reaches the combustion zone can be completed in an instant.

Free Chat

About Us

Contact Us